Generic / to specification · Cables, Connectors & Fibre

Fibre patch cords, pigtails and connectors

Passive fibre is where FTTH and transport projects actually spend most of their line items: not the OLT, but the thousands of patch cords, splitters, terminals and closures between it and the subscriber. None of it carries a manufacturer's part number that matters, which is why buyers describe it by specification rather than brand and why this page is organised that way. We source these to specification, in project quantities, with samples where a project needs them approved first.

How to read these part numbers

Read a patch cord as connector-end / connector-end / fibre type / simplex or duplex / length. SC/APC — angled, green — is the GPON and FTTH standard; LC/UPC — flat, blue — is what SFP ports take; mixing them costs 0.5 dB and a return loss problem. G.657A1 and A2 are bend-insensitive singlemode grades used in access; G.652D is the transport grade; OM3 and OM4 are multimode grades for 10G and 40G/100G short reach. PLC splitters are described by split ratio, then by packaging: bare, connectorised, LGX cassette or rack. ODFs, FATs and FDTs are described by fibre count and mounting. Closures are dome or inline, by fibre capacity.

Catalogue

Equipment reference

41 of 41 items
Part NumberModel / DesignationCompatibilityBand / InterfaceConditionLead TimeQuote
ADSS 24FADSS aerial cable, 24 fibreAerial backbone / accessG.652D, all-dielectric self-supporting, 100–200 m span (12 / 48 / 96 fibre on request)On enquiryOn enquiry
CLOSURE DOME 144Dome splice closure, 144 coreAerial / duct / direct buried144 fibres, IP68, mechanical sealOn enquiryOn enquiry
CLOSURE DOME 288Dome splice closure, 288 coreBackbone / duct288 fibres, IP68, mechanical sealOn enquiryOn enquiry
CLOSURE DOME 48Dome splice closure, 48 coreAerial / duct / direct buried48 fibres, 4 round ports + 1 oval, IP68, mechanical sealOn enquiryOn enquiry
CLOSURE DOME 96Dome splice closure, 96 coreAerial / duct / direct buried96 fibres, IP68, mechanical sealOn enquiryOn enquiry
CLOSURE INLINE 96Inline (horizontal) splice closure, 96 coreAerial / duct96 fibres, inline, IP68On enquiryOn enquiry
DROP CABLE 1C G657A2 1KMFTTH drop cable, 1 core, G.657A2, 1 kmFTTH last dropFlat 2 × 3 mm, FRP strength members, LSZH, 1 km drum (2-core on request)On enquiryOn enquiry
DROP CABLE 1C SELF-SUPPORT 1KMFTTH self-supporting drop cable, 1 core, 1 kmAerial FTTH dropFlat 2 × 5.2 mm with steel messenger, G.657A2, 1 km drumOn enquiryOn enquiry
FAST CONNECTOR SC/APCField-installable fast connector, SC/APCFTTH drop terminationSC/APC, pre-embedded fibre, for 2 × 3 mm / 2 × 5 mm drop cableOn enquiryOn enquiry
FAT 16Fibre access terminal, 16 core, IP65GPON ODN, pole / wall16 × SC/APC drop ports, 1:16 splitter slot, IP65On enquiryOn enquiry
FAT 8Fibre access terminal, 8 core, IP65GPON ODN, pole / wall8 × SC/APC drop ports, 1:8 splitter slot, IP65On enquiryOn enquiry
FDT 144Fibre distribution terminal, 144 coreGPON ODN, wall / pole144-fibre splice and distribution, splitter traysOn enquiryOn enquiry
FDT 48Fibre distribution terminal, 48 coreGPON ODN, wall / pole48-fibre splice and distribution, splitter trayOn enquiryOn enquiry
FDT 96Fibre distribution terminal, 96 coreGPON ODN, wall / pole96-fibre splice and distribution, up to 4 × 1:16 splittersOn enquiryOn enquiry
GYFTY 48FNon-metallic duct cable, 48 fibreDuct / backboneG.652D, loose tube, FRP central member (24 / 96 / 144 fibre on request)On enquiryOn enquiry
GYTS 96FArmoured duct / direct-buried cable, 96 fibreDuct / direct buriedG.652D, steel-tape armour, loose tube (24–288 fibre on request)On enquiryOn enquiry
LC-LC OM3 DX 3MMultimode patch cord, LC – LC, OM3, duplex, 3 m10G-SR / 40G-SR4 breakoutOM3 50/125 µm, aqua, LSZH, duplex (1–30 m on request)On enquiryOn enquiry
LC-LC OM4 DX 3MMultimode patch cord, LC – LC, OM4, duplex, 3 m10G / 25G / 100G-SROM4 50/125 µm, violet / aqua, LSZH, duplex (1–30 m on request)On enquiryOn enquiry
LC/UPC PIGTAIL SM 1.5MSinglemode pigtail, LC/UPC, 1.5 m, 12-colour setODF / splice traysG.652D SM, 0.9 mm tight buffer, 12 colours per setOn enquiryOn enquiry
LC/UPC-LC/UPC SM DX 3MSinglemode patch cord, LC/UPC – LC/UPC, duplex, 3 mSFP / SFP+ / QSFP LC portsG.652D SM, 2.0 mm LSZH, duplex, uniboot available (other lengths on request)On enquiryOn enquiry
LC/UPC-LC/UPC SM DX 3M ARMOUREDArmoured singlemode patch cord, LC – LC, duplex, 3 mOutdoor cabinets, RRU / BBU jumpersG.657A2 SM, stainless-steel armour, LSZH, duplexOn enquiryOn enquiry
LC/UPC-SC/UPC SM DX 3MSinglemode patch cord, LC/UPC – SC/UPC, duplex, 3 mSFP ports to SC ODFG.652D SM, 2.0 mm LSZH, duplexOn enquiryOn enquiry
MPO-12 OM4 TRUNK 10MMPO/MTP-12 to MPO/MTP-12 trunk, OM4, 10 m40G-SR4 / 100G-SR412-fibre OM4, female–female, Type B polarity (20 m, 30 m, 50 m on request)On enquiryOn enquiry
MPO-LC OM4 BREAKOUT 3MMPO/MTP-12 to 4 × LC duplex breakout, OM4, 3 m40G to 4 × 10G / 100G to 4 × 25G8-fibre OM4, MPO female to 4 × LC duplexOn enquiryOn enquiry
ODF 144 SC/APCOptical distribution frame, 144-port SC/APCOLT / transport racks19-inch, 144 SC/APC adaptors (LC duplex and SC/UPC variants on request)On enquiryOn enquiry
ODF 24 SC/APC 1UOptical distribution frame, 24-port SC/APC, 1U rackOLT / transport racks19-inch 1U, 24 SC/APC adaptors, pigtails and splice tray includedOn enquiryOn enquiry
ODF 48 LC DX 1UOptical distribution frame, 48-fibre LC duplex, 1U rackTransport / data-centre racks19-inch 1U, 24 LC duplex adaptors, SM or OM4On enquiryOn enquiry
ODF 48 SC/APC 2UOptical distribution frame, 48-port SC/APC, 2U rackOLT / transport racks19-inch 2U, 48 SC/APC adaptors, sliding drawerOn enquiryOn enquiry
ODF 96 SC/APC 4UOptical distribution frame, 96-port SC/APC, 4U rackOLT / transport racks19-inch 4U, 96 SC/APC adaptors, sliding drawerOn enquiryOn enquiry
PLC 1:16 SC/APCPLC splitter 1:16, SC/APC connectorisedGPON ODN, FAT / FDT1 × 16, 2.0 mm SC/APC pigtails, ≤ 13.7 dBOn enquiryOn enquiry
PLC 1:2 BAREPLC splitter 1:2, bare fibre, mini steel tubeGPON ODN1 × 2, 250 µm / 900 µm leads, 1260–1650 nm, ≤ 4.0 dBOn enquiryOn enquiry
PLC 1:32 1U RACKPLC splitter 1:32, 1U rack-mount, SC/APC19-inch OLT rack1 × 32 in 1U 19-inch enclosure, SC/APC adaptorsOn enquiryOn enquiry
PLC 1:32 SC/APCPLC splitter 1:32, SC/APC connectorisedGPON ODN, FDT / cabinet1 × 32, 2.0 mm SC/APC pigtails, ≤ 17.0 dBOn enquiryOn enquiry
PLC 1:4 BAREPLC splitter 1:4, bare fibre, mini steel tubeGPON ODN1 × 4, 1260–1650 nm, ≤ 7.2 dBOn enquiryOn enquiry
PLC 1:64 SC/APCPLC splitter 1:64, SC/APC connectorisedGPON ODN, cabinet1 × 64, 2.0 mm SC/APC pigtails, ≤ 20.5 dBOn enquiryOn enquiry
PLC 1:8 LGXPLC splitter 1:8, LGX cassette, SC/APC19-inch ODF / OLT rack1 × 8 in LGX module, SC/APC adaptors (1:16 and 1:32 LGX on request)On enquiryOn enquiry
PLC 1:8 SC/APCPLC splitter 1:8, SC/APC connectorisedGPON ODN, FAT / FDT1 × 8, 2.0 mm SC/APC pigtails, ≤ 10.5 dB (bare and LGX variants on request)On enquiryOn enquiry
SC/APC PIGTAIL SM 1.5MSinglemode pigtail, SC/APC, 1.5 m, 12-colour setODF / splice traysG.657A1 SM, 0.9 mm tight buffer, 12 colours per setOn enquiryOn enquiry
SC/APC-LC/UPC SM SX 3MSinglemode patch cord, SC/APC – LC/UPC, simplex, 3 mOLT / ODF to ONTG.657A1 SM, 2.0 mm LSZH, simplex (other lengths on request)On enquiryOn enquiry
SC/APC-SC/APC SM SX 3MSinglemode patch cord, SC/APC – SC/APC, simplex, 3 mGPON / FTTHG.657A1 SM, 2.0 mm LSZH, simplex (1 m, 2 m, 5 m, 10 m, 15 m on request)On enquiryOn enquiry
SC/UPC-SC/UPC SM DX 3MSinglemode patch cord, SC/UPC – SC/UPC, duplex, 3 mTransport / transmissionG.652D SM, 2.0 mm LSZH, duplex (other lengths on request)On enquiryOn enquiry

Ordering notes

For patch cords and pigtails state connector types, polish (APC or UPC), fibre grade, simplex or duplex, jacket diameter, length and quantity. For splitters give the ratio, the packaging and the connector type on the outputs. For terminals and closures give the fibre count, the mounting and the ingress rating you need. For cable give fibre count, construction (ADSS, duct, armoured, drop) and drum length. Tell us the project quantity and delivery schedule, because passive fibre is priced by volume and shipped by sea where the timeline allows. Condition is stated per quotation — new, new-surplus or refurbished — and where a destination does not admit used network equipment (Algeria is the usual example) we quote new. Hardware only: software licensing remains between the buyer and the manufacturer. Destination type approval and import permits (CST/SABER, TDRA, ICASA, CA, CMC, ARPCE) are the buyer's responsibility and we will say so on the quotation.

Lifecycle and availability

All items on this page are current production and are sourced new from qualified manufacturers to IEC and Telcordia specifications. Lead times are typically two to six weeks for project quantities, shorter for samples.

Equipment condition

New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.

New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.

Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.

Condition is confirmed in writing on every quotation before you commit to an order.

Warranty

Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.

Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.

Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.

Questions

Frequently asked questions

Do you supply branded passive fibre, or generic?

Generic to specification is the default and is what most projects tender for. Where a project specifies a brand — Corning, CommScope, Fujikura, YOFC — we source that brand and say so on the quotation.

Can you provide samples before a bulk order?

Yes. Samples of patch cords, splitters and terminals can be supplied for approval, usually within two weeks, and we recommend it for any item going into a tender-controlled project.

SC/APC or SC/UPC for GPON?

SC/APC. GPON optical budgets assume angled-polish connectors and the reflections from a UPC connector on a PON will cause problems. Use UPC only on point-to-point links and SFP ports.

Do you supply installation tools and test equipment?

On request — fusion splicers, OTDRs, power meters and cleavers can be included with a project order. Tell us at enquiry stage.

Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.

This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 22 August 2026.

Need a part number from Cables, Connectors & Fibre?

A structured offer follows within 72 hours.

Sending a full specification or a BOQ? Use the full RFQ form.