Huawei · Outdoor Cabinets & Enclosures

Huawei outdoor cabinets — ICC330, ICC710, TP48200A, APM30H and the PowerCube family

Huawei outdoor cabinets reach us in three forms of enquiry: a PowerCube 1000 integrated cabinet named by its full code (ICC330-H1-C4, ICC360-HA1-C1) for a new power site; a TP48200A outdoor power cabinet with rectifiers and SMU for a solar or hybrid rollout — the most recent request was for 49 cabinets with 12 kW rectifier sets; or an APM30H / TMC11H / IBBS200 stack to extend or replace a BTS3900A site. The table lists all three families with the climate variant, equipment space and battery fit where Huawei's own documentation states them, and says "confirmed per quotation" where it does not.

How to read these part numbers

ICC is the PowerCube 1000 integrated cabinet (Huawei's manuals expand it as integrated controller and converter; dealers write "integrated communication cabinet") and ESC the energy-storage cabinet that pairs with it. The number is a size series: ICC330 / ESC330 are 1600 × 650 × 650 mm, ICC710 / ESC710 are 1925 × 900 × 950 mm, ICC800 / ESC800 are 2000 × 800 × 800 mm. The letters that follow describe the climate units, read from the specification tables rather than defined by Huawei: H is a heat exchanger on the equipment bay (HEX100 at 150 W/K or HXC300S at 250 W/K), A a DC air conditioner (PC500D 600 W, PC1000D 1100 W, PC1500D-1 1500 W), D direct ventilation and N natural cooling — so H1 is heat exchanger only, HA1 heat exchanger plus air-conditioned battery bay, HD1 heat exchanger plus ventilated battery bay. The C-number is a configuration code that tracks equipment space and battery count (C8 is 22U with no internal battery; C10 and C5 are 8U with four lithium modules; C7 is 14U with twelve). TP48 is −48 V telecom power with the rated current after it (TP48200A = 200 A, TP48300A = 300 A); the two digits after the H/D/HX/HT/DT prefix track cabinet height in decimetres (HX09 = 900 mm, D14 = 1400 mm, H15 = 1500 mm, HT19 = 2030 mm including base) and the final A1/A5/C3/D1 is a configuration code. APM30H is the heat-exchanger outdoor power cabinet for BTS3900A and DBS3900 sites, with Ver.C/D/E hardware revisions; TMC11H is the matching transmission cabinet; IBBS200D and IBBS200T are the battery cabinets, D for direct ventilation and T for a built-in air conditioner.

Equipment reference

37 of 37 items

APM30

Model
APM30 outdoor power cabinet (earlier generation)
Compatibility
Huawei distributed base stations; 50 / 100 / 200 Ah extension battery cabinets
Band / Interface
600 × 700 × 480 mm excl. 200 mm base; <55 kg; DC output ≤3200 W, 0–60 A; internal batteries 12–36 Ah; IP55; −40 to +45 °C (heater below −20 °C)
Condition
On enquiry
Lead Time
On enquiry

APM30H

Also: Ver.C, Ver.D, Ver.E

Model
APM30H outdoor power cabinet for BTS3900A / DBS3900 sites
Compatibility
BBU3900 / BBU5900, BTS3900A, DBS3900 / DBS5900; AC input to −48 V DC
Band / Interface
700 × 600 × 480 mm excl. base; <76.5 kg excl. user equipment; heat exchanger with circulation fans; IP55; 220 V single-phase or 220 / 380 V three-phase variants
Condition
On enquiry
Lead Time
On enquiry

BTS3900A

Also: RFC / APM30H configurations

Model
BTS3900A outdoor macro base-station cabinet
Compatibility
BBU3900 / BBU5900; RRU / WRFU; APM30H, TMC11H, IBBS200 stackable
Band / Interface
700 × 600 × 480 mm per cabinet; 91–127 kg by configuration; RFC direct ventilation; IP55; −40 to +50 °C incl. solar radiation
Condition
On enquiry
Lead Time
On enquiry

BTS3900AL

Model
BTS3900AL outdoor macro base-station cabinet with integrated battery space
Compatibility
BBU3900; WRFU / RRU; transmission equipment
Band / Interface
1925 × 770 × 750 mm incl. base; 550 kg incl. base and full batteries; IP55; −40 to +50 °C
Condition
On enquiry
Lead Time
On enquiry

ESC330-A6

Model
PowerCube 1000 ESC330 outdoor battery cabinet, DC air-conditioned
Compatibility
Pairs with ICC330 cabinets; ESM-48100B1/B2, ESM-48150B1
Band / Interface
1600 × 650 × 650 mm; <110 kg; PC1500D-1 1500 W DC air conditioner; max 7 lithium modules; IP55; 0 to +45 °C
Condition
On enquiry
Lead Time
On enquiry

ESC330-D6

Model
PowerCube 1000 ESC330 outdoor battery cabinet, direct ventilation
Compatibility
Pairs with ICC330 cabinets; ESM lithium modules
Band / Interface
1600 × 650 × 650 mm; <110 kg; direct ventilation; max 7 lithium modules; IP34; 0 to +45 °C
Condition
On enquiry
Lead Time
On enquiry

ESC710-A1

Model
PowerCube 1000 ESC710 outdoor battery cabinet, DC air-conditioned, lead-acid
Compatibility
Pairs with ICC710 cabinets; FCB-A
Band / Interface
1925 × 900 × 1105 mm; <295 kg; PC1000D 1100 W DC air conditioner; 2 strings × 650 Ah; IP55; −10 to +45 °C
Condition
On enquiry
Lead Time
On enquiry

ESC710-D2

Model
PowerCube 1000 ESC710 outdoor battery cabinet, direct ventilation
Compatibility
Pairs with ICC710 cabinets; FCB-A
Band / Interface
1925 × 900 × 1105 mm; <240 kg; direct ventilation; 2 strings × 650 Ah; IP34; −10 to +40 °C
Condition
On enquiry
Lead Time
On enquiry

ESC800-A1

Model
PowerCube 1000 ESC800 outdoor energy-storage cabinet, DC air-conditioned
Compatibility
Pairs with ICC800-A1-C2
Band / Interface
2000 × 800 × 800 mm; ≈250 kg empty; max 20 × 3U lithium modules; DC air conditioner; IP55; 0 to +45 °C
Condition
On enquiry
Lead Time
On enquiry

IBBS200D

Also: IBBS200T

Model
IBBS200 outdoor battery cabinets — D direct ventilation, T built-in air conditioner
Compatibility
Backup for APM30H / BTS3900A / DBS3900 outdoor sites
Band / Interface
Two cabinets give up to 368 Ah backup; dimensions, weight and IP confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-A3

Model
PowerCube 1000 ICC330 outdoor cabinet, DC air-conditioned variant A3
Compatibility
PowerCube 1000
Band / Interface
ICC330 series housing; DC air conditioner; configuration confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-A6-F1

Model
PowerCube 1000 ICC330 outdoor cabinet, DC air-conditioned variant A6-F1
Compatibility
PowerCube 1000 solution tables
Band / Interface
ICC330 series housing; DC air conditioner; configuration confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-H1-C4

Model
PowerCube 1000 ICC330 outdoor integrated cabinet, heat-exchanger variant, config C4
Compatibility
PowerCube 1000; pairs with ESC330 battery cabinets
Band / Interface
ICC330 series housing 1600 × 650 × 650 mm; heat-exchanger equipment bay; U space and battery fit for this code confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-H1-C5

Model
PowerCube 1000 ICC330 outdoor integrated cabinet, heat-exchanger variant, config C5
Compatibility
PowerCube 1000; separate equipment and battery areas
Band / Interface
ICC330 series housing; 19-inch; IP55; RAL 7035; lead-acid or lithium packs optional; U space and cooling rating confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-H1-C6

Model
PowerCube 1000 ICC330 outdoor integrated cabinet, heat-exchanger variant, config C6
Compatibility
PowerCube 1000
Band / Interface
1600 × 650 mm; HEX100 heat exchanger; weight, U space and IP confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-H1-C8

Model
PowerCube 1000 ICC330 outdoor equipment cabinet, heat exchanger, no internal battery
Compatibility
R4875G5 / R4850G5 / R4850G2 rectifiers; batteries in a separate ESC330
Band / Interface
1600 × 650 × 650 mm (810 mm incl. door); <100 kg; 22U; HXC300S heat exchanger 250 W/K; IP55; −20 to +45 °C with solar load
Condition
On enquiry
Lead Time
On enquiry

ICC330-HA1-C10

Model
PowerCube 1000 ICC330 outdoor integrated cabinet, heat exchanger + DC air-conditioned battery bay
Compatibility
R4875G5 / R4850G5 / R4850G2; ESM-48100B1/B2, ESM-48150B1 lithium
Band / Interface
1600 × 650 × 650 mm; <100 kg; 8U; HEX100 150 W/K + PC500D 600 W DC air conditioner; max 4 lithium modules; IP55; 0 to +45 °C (−20 °C with heater)
Condition
On enquiry
Lead Time
On enquiry

ICC330-HD1-C2

Model
PowerCube 1000 ICC330 outdoor cabinet, heat exchanger + direct ventilation, config C2
Compatibility
PowerCube 1000
Band / Interface
ICC330 series housing; specification for this code confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC330-HD1-C5

Model
PowerCube 1000 ICC330 outdoor integrated cabinet, heat exchanger + direct-ventilation battery bay
Compatibility
R4875G5 / R4850G5 / R4850G2; ESM-48100B1/B2, ESM-48150B1 lithium
Band / Interface
1600 × 650 × 650 mm; <90 kg; 8U; HEX100 150 W/K + direct ventilation; max 4 lithium modules; IP55 equipment bay / IP34 battery bay; 0 to +45 °C
Condition
On enquiry
Lead Time
On enquiry

ICC330-HD3-C4

Model
PowerCube 1000 ICC330 outdoor integrated cabinet, HD3 climate, config C4
Compatibility
PowerCube 1000; hybrid / solar site power
Band / Interface
≈1500 × 600 × 650 mm, ≈105 kg (dealer listing); 6 rectifier slots; −40 to +75 °C storage; cooling rating and IP confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC360-HA1-C1

Model
Huawei ICC360 outdoor integrated cabinet, heat exchanger + DC cooling system
Compatibility
Huawei site power; quoted with 48 V / 100 Ah VRLA or ESM-48100A1 lithium bank, 50 A / 3000 W rectifier modules and UPEUe
Band / Interface
IP55 integrated cabinet with DC cooling system; quoted new-compatible in 100-unit lots; dimensions and U space confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ICC710-HA1-C7

Model
PowerCube 1000 ICC710 large outdoor integrated cabinet, heat exchanger + DC air conditioner
Compatibility
PowerCube 1000 rectifiers; ESM-48100B1 lithium
Band / Interface
1925 × 900 × 950 mm (1270 mm incl. door); <320 kg; 14U; HEX100 150 W/K + PC1500D-1 1500 W; max 12 lithium modules; IP55; 0 to +45 °C
Condition
On enquiry
Lead Time
On enquiry

ICC710-HA1H-C5

Model
PowerCube 1000 ICC710 outdoor integrated cabinet with lead-acid / FCB-A battery bay
Compatibility
FCB-A battery plus ESM-48100B1
Band / Interface
1925 × 900 × 950 mm; <320 kg; 13U; HEX100 150 W/K + PC1500D-1 1500 W; 4 × ESM-48100B1 + 1 × FCB-A; IP55; 0 to +45 °C (−20 °C with heater)
Condition
On enquiry
Lead Time
On enquiry

ICC800-A1-C2

Model
PowerCube 1000 ICC800 outdoor integrated cabinet, DC air-conditioned, solar / hybrid variant
Compatibility
PowerCube 1000 hybrid system; ESC800-A1; ETP48600-C5B1 power unit
Band / Interface
2000 × 800 × 800 mm; ≈250 kg empty; max 16 lithium modules; DC air conditioner; IP55; 0 to +45 °C; 0–4000 m
Condition
On enquiry
Lead Time
On enquiry

MTS9514A-AM2001

Model
MTS9514A outdoor telecom cabinet
Compatibility
Battery and telecom equipment installation
Band / Interface
2000 × 750 × 750 mm excl. 150 mm base; 18U user space plus 2 battery sets; LLVD 2 × 125 A + 3 × 63 A, BLVD 2 × 63 A, 2 × 32 A, 2 × 16 A; cooling and IP confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

PowerCube-G G302A

Model
PowerCube 1000 grid-hybrid integrated power and storage cabinet
Compatibility
Grid / solar hybrid sites; 11U customer space
Band / Interface
1825 × 770 × 1250 mm; <1243 kg; 5 × 50 A; 31.2 kWh storage; heat exchanger + DC air-conditioned battery bay; IP55; −20 to +50 °C
Condition
On enquiry
Lead Time
On enquiry

TBC300A-DCA5

Model
TBC300A outdoor battery cabinet
Compatibility
Pairs with TP48200A-HX09A1 / HX09A5, stacked or side by side
Band / Interface
900 × 650 × 650 mm excl. base; ≤50 kg without batteries; IP34; battery capacity confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

TMC11H

Also: WD2P048CAB29 (Ver.E)

Model
TMC11H outdoor transmission cabinet
Compatibility
BTS3900A, BTS3900, DBS3900, BTS3900L / AL / C, BTS5900 / DBS5900; houses BBU3900 at −48 V DC
Band / Interface
Heat-exchanger cooling; Ver.E ships with FAN02E, DCDU12B or 12C, ELU, door sensor and default cables; dimensions and weight confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

TP48200A-D14A1

Model
TP48200A outdoor power cabinet, direct ventilation, 1.4 m
Compatibility
Huawei −48 V site power
Band / Interface
1400 × 650 × 700 mm excl. base; direct ventilation >1500 W; >10U customer space; IP55 equipment bay / IP23 battery bay; −10 to +50 °C
Condition
On enquiry
Lead Time
On enquiry

TP48200A-DT19D1

Model
TP48200A outdoor power cabinet, direct ventilation, 2 m
Compatibility
Huawei −48 V site power
Band / Interface
2030 × 820 × 760 mm incl. base; <200 kg without rectifiers and batteries; IP55; direct ventilation
Condition
On enquiry
Lead Time
On enquiry

TP48200A-H15A5

Also: TP48200A-H15A3, TP48200A-D15A1

Model
TP48200A integrated outdoor power cabinet, 1.5 m, heat-exchanger equipment bay
Compatibility
Huawei −48 V site power; BTS and transmission equipment
Band / Interface
1500 × 650 × 650 mm excl. base; <120 kg; 4 rectifier slots, 11.6–12 kW; equipment bay HEX / battery bay direct ventilation; IP55 / IP45; −10 to +45 °C (D15A1 −40 °C)
Condition
On enquiry
Lead Time
On enquiry

TP48200A-HT15A5

Also: TP48200A-HT15A6, TP48200A-HT15B4

Model
TP48200A HT15 outdoor power cabinet series, 1.5 m
Compatibility
Huawei −48 V site power
Band / Interface
1.5 m class by naming; per-code specification confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

TP48200A-HT19C3

Also: TP48200A-HT19C4

Model
TP48200A large outdoor power cabinet, 2 m
Compatibility
Huawei −48 V site power; 19-inch customer equipment
Band / Interface
2030 × 820 × 760 mm incl. 150 mm base; ≤200 kg without rectifiers and batteries; equipment and battery compartments IP55; floor / rooftop / wall mount
Condition
On enquiry
Lead Time
On enquiry

TP48200A-HX09A1

Model
TP48200A outdoor power cabinet, 900 mm split type
Compatibility
Huawei −48 V site power; combines with TBC300A-DCA5
Band / Interface
900 × 650 × 650 mm excl. 100 mm base; ≤75 kg without rectifiers; IP55; floor or wall mount, front access
Condition
On enquiry
Lead Time
On enquiry

TP48200A-HX09A5

Model
TP48200A outdoor power cabinet, 900 mm split type, 12 kW rectifier set
Compatibility
Quoted with SMU02C, S4850G1 3000 W and S4875G 4000 W rectifiers; stacks on TBC300A battery cabinet
Band / Interface
900 × 650 × 650 mm class (HX09 series); 12 kW rectifier configuration; IP55; cooling variant confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

TP48200E-H09A1

Also: TP48200E-D09A1, TBC300A-DCA1, TBC300A-TCA1

Model
TP48200E split-type 900 mm outdoor power cabinets with TBC300A battery cabinets
Compatibility
Huawei −48 V site power
Band / Interface
900 × 650 × 650 mm; <70 kg excl. rectifiers and battery; heat exchanger (H) or direct ventilation (D); IP55 (battery cabinets IP34 / IP55); −40 or −10 to +45 °C by model
Condition
On enquiry
Lead Time
On enquiry

TP48300A-DX15A1

Model
TP48300A outdoor power cabinet, 300 A, three-phase, direct ventilation
Compatibility
Huawei −48 V site power, 220 / 380 V AC three-phase input
Band / Interface
1650 × 650 × 650 mm; 300 A; direct ventilation; weight and IP confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

Cannot find a part number? Send us the number and we will identify and price it.

Ordering notes

Give the full cabinet code with its suffix, because ICC330-H1-C8 and ICC330-HA1-C10 share a housing and differ entirely in what they will hold. State whether the site is AC- or DC-fed, the ambient range and solar exposure, the number of rectifier modules and the battery type and capacity you intend to fit, and whether the plinth or base frame is required. For TP48200A rollouts give the rectifier module (R48xx / S4850G1 / S4875G), the SMU model and the quantity per site so the cabinet, modules and monitoring are quoted as one line per site. For APM30H and TMC11H state the hardware version (Ver.C, D or E) because the fan unit, DCDU and rectifier shelf differ by version. Condition is stated per quotation — new, new surplus or refurbished with the cosmetic grade — and where a destination does not admit used network equipment we quote new. No list price is published; quotations are per cabinet with the configuration itemised — housing, climate unit, rectifier frame, modules, monitoring, batteries, plinth — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.

Lifecycle and availability

PowerCube 1000 (ICC330 / ICC710 / ICC800 with ESC cabinets, V300R007 and V300R008 manuals), PowerCube 500 and the PowerCube-G grid-hybrid cabinet are current Huawei site-power products. TP48200A and TP48300A outdoor power cabinets remain widely supplied new and as new surplus. APM30 / APM30H, TMC11H, IBBS200 and the BTS3900A / BTS3900AL cabinets belong to the 3900-series base-station generation and are supplied largely from refurbished and surplus stock, graded, with the hardware version stated. No official end-of-sale notice was found for any of these models; status is confirmed per quotation.

Configuring a PowerCube 1000 site — ICC plus ESC

A PowerCube 1000 site is an ICC equipment cabinet, optionally paired with an ESC battery cabinet of the same size series. The ICC carries the rectifier modules (R4875G5, R4850G5 or R4850G2), the site monitoring unit, the climate unit and either an internal battery bay or none. ICC330-H1-C8 gives the most equipment space (22U) and puts all batteries in an ESC330 next to it; ICC330-HA1-C10 and HD1-C5 give 8U and hold four ESM-48100B1/B2 or ESM-48150B1 lithium modules internally; ICC710-HA1-C7 gives 14U and twelve lithium modules; ICC800-A1-C2 is the solar and hybrid variant with sixteen lithium modules and an ETP48600 power unit.

Tell us the equipment to be housed in U, the battery autonomy required in hours and the site's power source — grid, grid-plus-solar or diesel-hybrid — and we will return the ICC and ESC combination, rectifier count and battery count rather than leave the buyer to match codes.

TP48200A power cabinets — the 12 kW site standard

The TP48200A family is the outdoor power cabinet most often requested for solar and hybrid rollouts: a 900 mm split type (TP48200A-HX09A1 / HX09A5, stacked on a TBC300A battery cabinet), a 1.5 m integrated cabinet (H15A3 / H15A5 / D15A1, heat-exchanger equipment bay with a ventilated battery bay, 11.6–12 kW rectifier set) and a 2 m cabinet (HT19C3 / HT19C4 / DT19D1, 2030 × 820 × 760 mm). A complete site is quoted as the cabinet, the rectifier modules (four 50 A slots on the 1.5 m type), the SMU02C monitoring unit and the battery strings. The TP48300A-DX15A1 is the 300 A, three-phase version for larger sites.

Replacing or extending a BTS3900A site

A BTS3900A outdoor site is a stack of 700 × 600 × 480 mm cabinets: the RFC radio cabinet, the APM30H power cabinet (heat exchanger, AC input to −48 V DC), the TMC11H transmission cabinet and one or two IBBS200 battery cabinets. Spares are ordered by cabinet and hardware version — a TMC11H Ver.E ships with FAN02E, DCDU12B or 12C, ELU and door sensor — and the quotation lists the fitted items rather than assuming them. Used APM30H and TMC11H units are graded and their fan units, heat exchangers and DCDUs tested before dispatch.

Equipment condition

New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.

New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.

Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.

Condition is confirmed in writing on every quotation before you commit to an order.

Warranty

Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.

Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.

Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.

Refurbished stock — how it is graded and what ships

New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.

Is the housing new?
Cosmetic grade. Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
Is it fully working?
Test coverage. Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
With plinth, keys and internal fittings?
What ships with the cabinet. The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
What warranty?
Warranty on used stock. Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
Is the firmware in English, and is it locked?
Firmware state. The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
What about licences on a used OLT?
Licence state (OLT chassis and control boards). Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.

Frequently asked questions

It is a PowerCube 1000 ICC330 housing (1600 × 650 × 650 mm series) with a heat-exchanger-cooled equipment bay in configuration C4. Huawei's public manuals list it in the solution tables alongside ESC330 battery cabinets but do not publish a per-code specification, so the equipment space and battery fit for this exact code are confirmed per quotation; the C8, C10 and C5 siblings are fully specified in the table above.

Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.

This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 22 August 2026.

Need a part number from Outdoor Cabinets & Enclosures?

A structured offer follows within 72 hours.

Sending a full specification or a BOQ? Use the full RFQ form.