Nokia · Outdoor Cabinets & Enclosures

Nokia outdoor cabinets — Flexi FCOA and FCOB, AirScale AMOB, AMOD, ACOA, ACOB and AAOB

Nokia outdoor housings are requested in lots that mirror a rollout: the current enquiry is for one hundred AAOB Outdoor Cabinet L units — the AirScale dual-bay power and battery cabinet — alongside refurbished Flexi FCOA cabinets from European decommissioning stock. The Flexi generation (FCOA, FCOS, FCOB) houses Flexi Multiradio modules in open 19-inch space; the AirScale generation splits into the AMOB and AMOD outdoor subracks that hold the plug-in units directly, the ACOA / ACOB 13U and 21U outdoor cabinets with their own climate and battery strings, and the all-in-one AAOB. The table states what Nokia's product descriptions and datasheets confirm and marks the AAOB attributes that must be confirmed per quotation.

How to read these part numbers

Flexi codes read FC for Flexi Cabinet, I for indoor or O for outdoor, and a variant letter: FCIA is the indoor cabinet (36 HU, IP20), FCOA the outdoor cabinet (30+5+5 HU, product code 470142A), FCOS the outdoor small, FCOB the later outdoor cabinet with a PDU box (473240A). Nokia product codes are six digits and a letter with a suffix for hardware revision (.101, .102). AirScale codes read AM for the AirScale subrack — AMIA indoor, AMOB and AMOD outdoor, 8U and 11U — and AC for the AirScale Cabinet Outdoor models ACOA (13U) and ACOB (21U), which can be stacked to 34U. AAOB "Outdoor Cabinet L (ST)" (CS7156103) is the AirScale all-in-one outdoor cabinet; Nokia has not published a datasheet defining the S / M / L sizes or the ST climate code, so those attributes are confirmed per quotation rather than stated.

Equipment reference

9 of 9 items

470142A

Also: FCOA, 470142A.102

Model
Flexi Cabinet for Outdoor (FCOA)
Compatibility
Flexi WCDMA, EDGE and Multiradio modules in open 19-inch space; options FCSA site support, FCFA air filter, FPRA rectifier, FCCA battery kit, FSEB / FSEC alarm and OVP
Band / Interface
30+5+5 HU; aluminium; empty weight ≤80 kg; air-cooled with or without FCFA filter; door lock + alarm switch; GR-63 Zone 4; quoted refurbished from European decommissioning stock (30-unit lot); overall H × W × D confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

473240A

Also: FCOB

Model
Flexi Cabinet Outdoor B with PDU box
Compatibility
Flexi and AirScale system modules outdoors; 4U × 350 mm 19-inch internal space, max 25 kg module; DC in 50 A, DC out 1500 W + 180 W
Band / Interface
≈600 × 380 × 600 mm; ≤29 kg without site bag; IP55; −40 to +45 °C; −40.5 to −57 V DC (−36 to −60 V extended); climate method confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

473952A

Also: AMOB, 473952A.102

Model
AirScale System Module Outdoor (AMOB), self-contained outdoor subrack
Compatibility
Up to 2 AirScale common units (ASIA / ASIB / ASIK) + 6 capacity units (ABIA / ABIL)
Band / Interface
355 × 487 × 605 mm; 8U; 23 kg empty, 41.8 kg full; heat-exchanger cooling; IP55; −40 to +55 °C; −40.5 to −57 V DC; max ≈1744 W, 37 A
Condition
On enquiry
Lead Time
On enquiry

474930A

Also: AMOD

Model
AirScale System Module Outdoor (AMOD), larger outdoor subrack
Compatibility
AirScale common units (ASIA, ASIB, ASIK) and capacity units (ABIL); 2 common + 6 capacity max
Band / Interface
488 × 487 × 665 mm (+110 mm muffler); 11U; 35–37.5 kg empty, 56.3 kg full; IP55; −5 to +55 °C; max ≈1656 W, 35 A at −48 V
Condition
On enquiry
Lead Time
On enquiry

ACOA

Model
Nokia AirScale Cabinet Outdoor, 13U with plinth
Compatibility
19-inch AirScale baseband and transmission; one battery string 12 V 100 Ah
Band / Interface
959 × 650 × 751 mm with 275 mm plinth (834 mm with 150 mm plinth); 13U; 2000 W thermal capacity at 55 °C, fresh-air filter + fan, 950 W heater; IP55, UL50 3R, Seismic 4; −40 to +55 °C; weight confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ACOB

Model
Nokia AirScale Cabinet Outdoor, 21U with plinth
Compatibility
19-inch AirScale baseband and transmission; up to two battery strings 12 V 100 Ah
Band / Interface
1315 × 650 × 751 mm with 275 mm plinth (1190 mm with 150 mm plinth); 21U; 4000 W thermal capacity at 55 °C; 950 W heater; IP55, UL50 3R, Seismic 4; −40 to +55 °C; weight confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

ACOB + ACOA stacked

Model
Nokia AirScale Cabinet Outdoor, stacked 34U configuration
Compatibility
As ACOA / ACOB, two cabinets stacked
Band / Interface
1999 × 650 × 751 mm with 275 mm plinth; 34U; 6000 W thermal capacity at 55 °C; IP55, UL50 3R, Seismic 4; −40 to +55 °C
Condition
On enquiry
Lead Time
On enquiry

CS7156103

Also: AAOB

Model
Nokia AAOB Outdoor Cabinet L (ST) — AirScale all-in-one outdoor dual-bay power / battery cabinet
Compatibility
Pre-integrated AirScale baseband, transmission, Nokia rectifiers and batteries; dual-bay cooling (electronics and batteries separately)
Band / Interface
Quoted new-compatible and used-original in 100-unit lots; size L, ST climate variant; dimensions, U space, cooling rating and battery capacity confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

FCOS

Model
Flexi Cabinet Outdoor Small
Compatibility
Flexi modules; optional item in the FCOA delivery list
Band / Interface
Dimensions, weight and HU capacity confirmed per quotation
Condition
On enquiry
Lead Time
On enquiry

Cannot find a part number? Send us the number and we will identify and price it.

Ordering notes

Give the product code with its revision suffix, because accessories and module compatibility differ between .101 and .102 builds. For FCOA state which optional items are required — FCSA site support module, FPRA rectifier, FCCA battery kit, FCFA air filter for coastal sites — since the cabinet itself is an empty aluminium housing with no electrical function. For AMOB and AMOD state the common and capacity units to be fitted. For AAOB give the quantity, destination and whether new-compatible or original used stock is acceptable: both have been quoted in recent enquiries and the quotation states which. Condition is stated per quotation — new, new surplus or refurbished with the cosmetic grade — and where a destination does not admit used network equipment we quote new. No list price is published; quotations are per cabinet with the configuration itemised — housing, climate unit, rectifier frame, modules, monitoring, batteries, plinth — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.

Lifecycle and availability

Flexi Multiradio cabinets (FCOA, FCIA, FCOS) are legacy Nokia Siemens Networks products supplied refurbished and graded from decommissioning stock. FCOB and the AMOB / AMOD subracks are AirScale-era and still referenced in Nokia roadmaps; the ACOA / ACOB cabinets and the all-in-one AAOB cabinet family are Nokia's current site-solution offer, supplied new and as new-compatible builds. No end-of-sale notice was found for any model; status is confirmed per quotation.

Flexi FCOA — an empty housing, quoted with its options

The FCOA is an aluminium outdoor cabinet with 30+5+5 HU of open 19-inch space, a door lock and door alarm switch, air-cooled with or without the FCFA filter (the filter version is for coastal sites above 8 mg/m²/day salt deposition), and no electrical functionality of its own. Everything that makes it a working site — FCSA site support module, FPRA rectifier, FCCA battery mounting kit and batteries, FSEB external alarm and FSEC overvoltage protection — is an optional item and is listed separately on the quotation. Empty weight is a maximum of 80 kg with four M12 lifting eyes.

Equipment condition

New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.

New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.

Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.

Condition is confirmed in writing on every quotation before you commit to an order.

Warranty

Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.

Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.

Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.

Refurbished stock — how it is graded and what ships

New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.

Is the housing new?
Cosmetic grade. Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
Is it fully working?
Test coverage. Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
With plinth, keys and internal fittings?
What ships with the cabinet. The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
What warranty?
Warranty on used stock. Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
Is the firmware in English, and is it locked?
Firmware state. The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
What about licences on a used OLT?
Licence state (OLT chassis and control boards). Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.

Frequently asked questions

FCOA takes Flexi WCDMA, EDGE and Multiradio modules in open 19-inch space. FCOB, AMOB and AMOD take AirScale and Flexi system modules at −48 V DC (−40.5 to −57 V): AMOB and AMOD hold up to two common units and six capacity units. The exact module list is confirmed with the dealer before ordering.

Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.

This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 22 August 2026.

Need a part number from Outdoor Cabinets & Enclosures?

A structured offer follows within 72 hours.

Sending a full specification or a BOQ? Use the full RFQ form.