ZTE · Outdoor Cabinets & Enclosures
ZTE outdoor cabinets — ZXDU68 W-series power cabinets, ZXDT22 and the BS8900 base-station cabinets
ZTE outdoor cabinets fall into two families that buyers often confuse: the ZXDU W-series outdoor DC power cabinets (W201 at 12 kW, W301 at 18 kW, W701 at 42 kW, ZXDU58 W121 at 120 A) and the newer ZXDUPA-WR12, which are power cabinets with rectifier slots and a battery compartment; and the ZXSDR BS8900A / BS8900B cabinet stacks, which house a ZTE baseband and radio units. The ZXDT22 SF01 integrated power energy system sits between them for sites with weak or no mains. This page lists each with the capacity, rectifier type and climate data ZTE's own descriptions state, and flags the models whose dimensions vary between hardware versions.
How to read these part numbers
ZXDU is ZTE's DC power family; the letter after the generation number gives the form factor: B is an embedded 19-inch shelf, S and T are indoor floor cabinets, W is the outdoor cabinet. A ZXDU68 B301 is therefore an 8U shelf and not an outdoor cabinet. The digits after W track capacity class — W201 is 12 kW with four ZXD3000 rectifiers, W301 18 kW with six, W701 42 kW with fourteen, ZXDU58 W121 is 120 A with four ZXD1500 modules. The version in brackets (V4.0, V5.0, V6.0) matters because rectifier modules are version-specific. ZXDUPA-WR12 is the current outdoor line with 4 kW ZXEPS rectifiers and DC air conditioners. ZXDT22 SF01 is the integrated power energy system, offered in five cabinet sizes from 900 to 2100 mm tall. ZXSDR is the base-station family: BS8900A and BS8900B are the outdoor macro cabinets, built as a BC baseband cabinet, RC radio cabinets and a PC battery cabinet stacked or side by side; BS8906 is the outdoor micro; BS8800 is IP20 and indoor, and BS8700 is a distributed BBU-plus-RRU product with no cabinet.
Equipment reference
17 of 17 items
| Part Number | Model / Designation | Compatibility | Band / Interface | Condition | Lead Time | |
|---|---|---|---|---|---|---|
| ZXDT22 SF01 1050 | ZTE Integrated Power Energy System, independent device cabinet, small | 2U subrack up to 6 rectifier / PU modules, 3U up to 9; ZXDT22 3000 W rectifier; solar-ready | 900 × 700 × 700 mm excl. base; heat exchanger + circulating fan; rectifier 3000 W, ≥96 % efficiency, 53.5 V; weight and IP confirmed per quotation | On enquiry | On enquiry | |
| ZXDT22 SF01 1750 | ZTE Integrated Power Energy System, independent device cabinet, large | As SF01 1050 with reserved equipment space | 1600 × 700 × 700 mm excl. base; direct ventilation or heat exchanger; weight and IP confirmed per quotation | On enquiry | On enquiry | |
| ZXDT22 SF01 1800 (12 V) | ZTE integrated cabinet with two layers of built-in 12 V batteries | Lead-acid and 12 V LiFePO4 batteries; rectifier subrack | 1600 × 700 × 700 mm excl. base; 2 battery layers; heat exchanger, optionally + 500 W air conditioner; weight, IP and Ah confirmed per quotation | On enquiry | On enquiry | |
| ZXDT22 SF01 2200 (12 V) | ZTE integrated cabinet with three layers of built-in 12 V batteries | Lead-acid and 12 V LiFePO4 batteries | 2000 × 700 × 700 mm excl. base; 3 battery layers; heat exchanger, optionally + 500 W air conditioner; weight, IP and Ah confirmed per quotation | On enquiry | On enquiry | |
| ZXDT22 SF01 2200 (2 V) | ZTE integrated cabinet for 2 V lead-acid cells | 2 V lead-acid cells in series | 2100 × 1050 × 1050 mm excl. base; heat exchanger, optionally + 500 W air conditioner; weight, IP and Ah confirmed per quotation | On enquiry | On enquiry | |
| ZXDU58 W121 (V4.0) | ZTE outdoor integrated communication power cabinet, 120 A | Up to 4 × ZXD1500 −48 V / 30 A rectifiers, ZXDU58 B monitoring; 220 V single or 380 V three-phase | 1745 × 600 × 600 mm combined (splits into two 945 mm cabinets); ≈200 kg excl. modules and batteries; 120 A, −53.5 V; AC 80–300 V; IP55; −40 to +55 °C | On enquiry | On enquiry | |
| ZXDU68 W201 (V5.0) | ZTE outdoor DC power cabinet, 12 kW, battery compartment in lower section | 4 × ZXD3000 rectifiers, CSU controller, SIU; 2 battery packs | 1930 × 650 × 650 mm (DC1 build; other versions 2000 × 600 × 600 or 2100 × 750 × 700 mm); ≈150 kg without modules; 800 W heat exchanger + 200 W TEC battery cabin; 12 kW, 254 A, −53.5 V; −20 to +50 °C; IP confirmed per quotation | On enquiry | On enquiry | |
| ZXDU68 W301 (V5.0) | ZTE outdoor DC power cabinet, 18 kW | 6 × ZXD3000 3 kW rectifiers, CSU; battery compartment | 18 kW, −53.5 V DC; AC input 85–295 V; rectifier efficiency 96.3 %; ≈2000 × 600 × 600 mm (dealer figure); climate options heat exchanger / TEC / air conditioner; weight and IP confirmed per quotation | On enquiry | On enquiry | |
| ZXDU68 W701 (V6.0) | ZTE outdoor DC power system for one-cabinet sites, 42 kW / 700 A | Up to 14 × 3000 W rectifiers, CSU; mains, generator and solar inputs; 3G / 4G / 5G co-site | 42 kW, 700 A, −53.5 V; 900 Ah battery backup, 3 × 125 A battery MCBs; rectifier efficiency up to 98 %; air conditioner / heat exchanger / DC fan options; dimensions and IP confirmed per quotation | On enquiry | On enquiry | |
| ZXDUPA-WR12 KZ OECAlso: 041100.2*A24 | ZTE outdoor DC power system up to 24 kW with battery shelf and DC air conditioners | Up to 6 × ZXEPS R4875F1 4000 W rectifiers, ZXDT02 PU3000 solar module, CSU603A; 2 groups 12 V lead-acid or 4 × 48 V 3U lithium | 24 kW; 2 × 1600 W DC air conditioners 1+1 + 600 W heater, equipment bay 10–25 °C; battery shelf 560 × 600 × 330 mm (≥250 kg); IP55; −40 to +45 °C; overall dimensions confirmed per quotation | On enquiry | On enquiry | |
| ZXG10 BS30 | ZTE compact outdoor GSM BTS (legacy) | GSM 900 / 1800; max S222; cascade up to 4 sites | 580 × 400 × 284 mm; ≈39 kg; heat-pipe cooling with heater; IP55; −40 to +55 °C; 260 W | On enquiry | On enquiry | |
| ZXSDR BS8900A BC8910A | BS8900A outdoor macro base station — baseband / site support cabinet | B8200-class BBU, built-in AC / DC power, heat exchanger, transmission space; pairs with RC8910A / RC8911A and PC8910A; RSU40 / 60 / 82 | 800 × 600 × 600 mm; heat exchanger in door; 220 V AC (150–300 V) or −48 V DC; IP55; −40 to +55 °C; weight confirmed per quotation | On enquiry | On enquiry | |
| ZXSDR BS8900A PC8910A | BS8900A outdoor battery cabinet, direct ventilation or TEC | BS8900A stack; 2 battery groups of 2 × 135 Ah or 2 × 90 Ah | 800 × 600 × 600 mm; direct-ventilation variant ≤10 °C rise, TEC variant ≤15 °C; each rack up to 260 kg; concrete base >1600 × 1500 mm stacked; IP confirmed per quotation | On enquiry | On enquiry | |
| ZXSDR BS8900A RC8910A | BS8900A outdoor radio cabinet, 6 RSU | Up to 6 RSU (e.g. RSU82); stacks with BC8910A | 850 × 600 × 600 mm; forced-air cooling; IP55; typical stack 1600 × 600 × 600 mm ≈185 kg; full system <260 kg (3 sectors) to 300 kg (6 sectors) without battery | On enquiry | On enquiry | |
| ZXSDR BS8900A RC8911A | BS8900A outdoor radio cabinet, 3 RSU + battery side | 3 RSU right-hand side; one 90 / 150 Ah battery set left-hand side | 850 × 600 × 600 mm; fan control subsystem; IP55; weight confirmed per quotation | On enquiry | On enquiry | |
| ZXSDR BS8900BAlso: RC8910B, BC8912B, BC8911B | BS8900B integrated outdoor macro base station, two-cabinet | Single rack up to 108 GSM TRX, 60 UMTS carriers, 18 LTE MIMO cells; RSU82; 90 / 150 / 300 Ah battery backup | RC8910B 1750 × 750 × 700 mm, 305 kg; BC8912B / BC8911B 1600 × 700 × 700 mm, 150 kg; −48 V DC or 220 / 110 V AC; IP55; heat exchange rating confirmed per quotation | On enquiry | On enquiry | |
| ZXSDR BS8906EAlso: BC8906 + RC8906 | BS8906E outdoor micro base station | BBU, RSU, FCE, PSU; GSM / UMTS; 4C3S | 600 × 420 × 480 mm single cabinet (each half 600 × 210 × 480 mm); ≤70 kg total; fan array; IP55; −40 to +55 °C; −48 V DC or 110 / 220 V AC; another ZTE deck gives 650 × 320 × 480 mm, 52 kg | On enquiry | On enquiry |
ZXDT22 SF01 1050
- Model
- ZTE Integrated Power Energy System, independent device cabinet, small
- Compatibility
- 2U subrack up to 6 rectifier / PU modules, 3U up to 9; ZXDT22 3000 W rectifier; solar-ready
- Band / Interface
- 900 × 700 × 700 mm excl. base; heat exchanger + circulating fan; rectifier 3000 W, ≥96 % efficiency, 53.5 V; weight and IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDT22 SF01 1750
- Model
- ZTE Integrated Power Energy System, independent device cabinet, large
- Compatibility
- As SF01 1050 with reserved equipment space
- Band / Interface
- 1600 × 700 × 700 mm excl. base; direct ventilation or heat exchanger; weight and IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDT22 SF01 1800 (12 V)
- Model
- ZTE integrated cabinet with two layers of built-in 12 V batteries
- Compatibility
- Lead-acid and 12 V LiFePO4 batteries; rectifier subrack
- Band / Interface
- 1600 × 700 × 700 mm excl. base; 2 battery layers; heat exchanger, optionally + 500 W air conditioner; weight, IP and Ah confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDT22 SF01 2200 (12 V)
- Model
- ZTE integrated cabinet with three layers of built-in 12 V batteries
- Compatibility
- Lead-acid and 12 V LiFePO4 batteries
- Band / Interface
- 2000 × 700 × 700 mm excl. base; 3 battery layers; heat exchanger, optionally + 500 W air conditioner; weight, IP and Ah confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDT22 SF01 2200 (2 V)
- Model
- ZTE integrated cabinet for 2 V lead-acid cells
- Compatibility
- 2 V lead-acid cells in series
- Band / Interface
- 2100 × 1050 × 1050 mm excl. base; heat exchanger, optionally + 500 W air conditioner; weight, IP and Ah confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDU58 W121 (V4.0)
- Model
- ZTE outdoor integrated communication power cabinet, 120 A
- Compatibility
- Up to 4 × ZXD1500 −48 V / 30 A rectifiers, ZXDU58 B monitoring; 220 V single or 380 V three-phase
- Band / Interface
- 1745 × 600 × 600 mm combined (splits into two 945 mm cabinets); ≈200 kg excl. modules and batteries; 120 A, −53.5 V; AC 80–300 V; IP55; −40 to +55 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDU68 W201 (V5.0)
- Model
- ZTE outdoor DC power cabinet, 12 kW, battery compartment in lower section
- Compatibility
- 4 × ZXD3000 rectifiers, CSU controller, SIU; 2 battery packs
- Band / Interface
- 1930 × 650 × 650 mm (DC1 build; other versions 2000 × 600 × 600 or 2100 × 750 × 700 mm); ≈150 kg without modules; 800 W heat exchanger + 200 W TEC battery cabin; 12 kW, 254 A, −53.5 V; −20 to +50 °C; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDU68 W301 (V5.0)
- Model
- ZTE outdoor DC power cabinet, 18 kW
- Compatibility
- 6 × ZXD3000 3 kW rectifiers, CSU; battery compartment
- Band / Interface
- 18 kW, −53.5 V DC; AC input 85–295 V; rectifier efficiency 96.3 %; ≈2000 × 600 × 600 mm (dealer figure); climate options heat exchanger / TEC / air conditioner; weight and IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDU68 W701 (V6.0)
- Model
- ZTE outdoor DC power system for one-cabinet sites, 42 kW / 700 A
- Compatibility
- Up to 14 × 3000 W rectifiers, CSU; mains, generator and solar inputs; 3G / 4G / 5G co-site
- Band / Interface
- 42 kW, 700 A, −53.5 V; 900 Ah battery backup, 3 × 125 A battery MCBs; rectifier efficiency up to 98 %; air conditioner / heat exchanger / DC fan options; dimensions and IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXDUPA-WR12 KZ OEC
Also: 041100.2*A24
- Model
- ZTE outdoor DC power system up to 24 kW with battery shelf and DC air conditioners
- Compatibility
- Up to 6 × ZXEPS R4875F1 4000 W rectifiers, ZXDT02 PU3000 solar module, CSU603A; 2 groups 12 V lead-acid or 4 × 48 V 3U lithium
- Band / Interface
- 24 kW; 2 × 1600 W DC air conditioners 1+1 + 600 W heater, equipment bay 10–25 °C; battery shelf 560 × 600 × 330 mm (≥250 kg); IP55; −40 to +45 °C; overall dimensions confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXG10 BS30
- Model
- ZTE compact outdoor GSM BTS (legacy)
- Compatibility
- GSM 900 / 1800; max S222; cascade up to 4 sites
- Band / Interface
- 580 × 400 × 284 mm; ≈39 kg; heat-pipe cooling with heater; IP55; −40 to +55 °C; 260 W
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXSDR BS8900A BC8910A
- Model
- BS8900A outdoor macro base station — baseband / site support cabinet
- Compatibility
- B8200-class BBU, built-in AC / DC power, heat exchanger, transmission space; pairs with RC8910A / RC8911A and PC8910A; RSU40 / 60 / 82
- Band / Interface
- 800 × 600 × 600 mm; heat exchanger in door; 220 V AC (150–300 V) or −48 V DC; IP55; −40 to +55 °C; weight confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXSDR BS8900A PC8910A
- Model
- BS8900A outdoor battery cabinet, direct ventilation or TEC
- Compatibility
- BS8900A stack; 2 battery groups of 2 × 135 Ah or 2 × 90 Ah
- Band / Interface
- 800 × 600 × 600 mm; direct-ventilation variant ≤10 °C rise, TEC variant ≤15 °C; each rack up to 260 kg; concrete base >1600 × 1500 mm stacked; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXSDR BS8900A RC8910A
- Model
- BS8900A outdoor radio cabinet, 6 RSU
- Compatibility
- Up to 6 RSU (e.g. RSU82); stacks with BC8910A
- Band / Interface
- 850 × 600 × 600 mm; forced-air cooling; IP55; typical stack 1600 × 600 × 600 mm ≈185 kg; full system <260 kg (3 sectors) to 300 kg (6 sectors) without battery
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXSDR BS8900A RC8911A
- Model
- BS8900A outdoor radio cabinet, 3 RSU + battery side
- Compatibility
- 3 RSU right-hand side; one 90 / 150 Ah battery set left-hand side
- Band / Interface
- 850 × 600 × 600 mm; fan control subsystem; IP55; weight confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXSDR BS8900B
Also: RC8910B, BC8912B, BC8911B
- Model
- BS8900B integrated outdoor macro base station, two-cabinet
- Compatibility
- Single rack up to 108 GSM TRX, 60 UMTS carriers, 18 LTE MIMO cells; RSU82; 90 / 150 / 300 Ah battery backup
- Band / Interface
- RC8910B 1750 × 750 × 700 mm, 305 kg; BC8912B / BC8911B 1600 × 700 × 700 mm, 150 kg; −48 V DC or 220 / 110 V AC; IP55; heat exchange rating confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ZXSDR BS8906E
Also: BC8906 + RC8906
- Model
- BS8906E outdoor micro base station
- Compatibility
- BBU, RSU, FCE, PSU; GSM / UMTS; 4C3S
- Band / Interface
- 600 × 420 × 480 mm single cabinet (each half 600 × 210 × 480 mm); ≤70 kg total; fan array; IP55; −40 to +55 °C; −48 V DC or 110 / 220 V AC; another ZTE deck gives 650 × 320 × 480 mm, 52 kg
- Condition
- On enquiry
- Lead Time
- On enquiry
Cannot find a part number? Send us the number and we will identify and price it.
Ordering notes
Give the model with its version — ZXDU68 W201 V5.0 and V6.0 take different rectifiers — and the rectifier count, controller (CSU500B, CSU510B, CSU602A, CSU603A) and climate hardware required. Because W201 dimensions appear as 1930 × 650 × 650, 2000 × 600 × 600 and 2100 × 750 × 700 mm in different ZTE documents, a used cabinet is quoted against its nameplate and measured dimensions, not the model name alone. For BS8900A sites name each cabinet in the stack (BC8910A, RC8910A or RC8911A, PC8910A) and the RSU count. Condition is stated per quotation — new, new surplus or refurbished with the cosmetic grade — and where a destination does not admit used network equipment we quote new. No list price is published; quotations are per cabinet with the configuration itemised — housing, climate unit, rectifier frame, modules, monitoring, batteries, plinth — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.
Lifecycle and availability
ZXDU68 W701 V6.0 and ZXDUPA-WR12 are current ZTE outdoor power products with recent product descriptions. ZXDU68 W201 / W301 V5.0 and ZXDU58 W121 V4.0 are earlier generations still listed in ZTE's document index and supplied new surplus and refurbished. ZXSDR BS8900A / BS8900B / BS8906 cabinets date from the 2G/3G and early LTE era and are supplied refurbished for expansion or swap-out of existing sites. No end-of-sale notice was found for any model; status and hardware version are confirmed per quotation.
Specifying a ZXDU W-series cabinet
A W-series cabinet is quoted as the housing with its climate unit, the CSU controller, the rectifier modules fitted and the battery provision. W201 houses four ZXD3000 modules for 12 kW with an 800 W heat exchanger on the equipment cabin and a 200 W thermoelectric cooler on the battery cabin; W301 houses six for 18 kW; W701 houses fourteen for 42 kW with air-conditioner, heat-exchanger or DC-fan options and mains, generator and solar inputs. ZXDUPA-WR12 houses six 4 kW ZXEPS R4875F1 rectifiers for 24 kW with two 1600 W DC air conditioners in 1+1 and a 600 W heater, holding the equipment compartment at 10–25 °C. State the load in kW, the battery autonomy and the ambient range and the quotation names the model and version.
Equipment condition
New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.
New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.
Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.
Condition is confirmed in writing on every quotation before you commit to an order.
Warranty
Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.
Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.
Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.
Refurbished stock — how it is graded and what ships
New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.
- Is the housing new?
- Cosmetic grade. Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
- Is it fully working?
- Test coverage. Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
- With plinth, keys and internal fittings?
- What ships with the cabinet. The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
- What warranty?
- Warranty on used stock. Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
- Is the firmware in English, and is it locked?
- Firmware state. The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
- What about licences on a used OLT?
- Licence state (OLT chassis and control boards). Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.
Frequently asked questions
No. The B-series are embedded 19-inch power shelves — the B301 is 8U, 482 mm wide, with six rectifier slots — and need an outdoor cabinet or shelter around them. The outdoor cabinets are the W-series and ZXDUPA-WR12 on this page. Check the nameplate letter before agreeing a model.
Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.
This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 22 August 2026.
Need a part number from Outdoor Cabinets & Enclosures?
A structured offer follows within 72 hours.