EnerSys, ANDREW, Rittal, nVent SCHROFF · Outdoor Cabinets & Enclosures
Outdoor cabinets from other manufacturers — EnerSys, ANDREW, Rittal and nVent SCHROFF
Beyond the radio vendors and the Vertiv, Delta and Eltek ranges, operators and contractors also specify outdoor housings from enclosure and battery specialists: EnerSys SiteFlex power and battery cabinets, ANDREW macro and micro cell site enclosures, Rittal CS Toptec bayable outdoor enclosures, nVent SCHROFF outdoor cabinets for telecom and railway electronics, and the Flexenclosure eSite sealed hybrid power system. The table lists each model by its manufacturer part number with dimensions, 19-inch space, climate option and ingress rating as published by the manufacturer. Quotations itemise the housing, climate unit, power system and batteries as separate lines.
How to read these part numbers
EnerSys SiteFlex cabinets are ordered by a ten-digit article number such as 2000005674; the model name gives the function — MPC for the outdoor power and battery enclosure, LCC for the battery cabinets — and for the LCC range the battery format, LCC 8-12 and 16-12 for 12 V blocks and LCC 24-2 for 2 V cells, with the suffix F for direct air cooling and A for an air-conditioned cabinet. ANDREW site enclosures carry A-100xxx numbers, one per configured enclosure, with the rectifier and battery fit defined by the code. Rittal CS Toptec enclosures are numbered CS 97xx.xxx and are given as width × height × depth; the climate control unit is a separate order. nVent SCHROFF outdoor cabinets use article numbers of the form 11249-016 and are rated by heat dissipation in W/K for natural convection, fan ventilation or a door-mounted heat exchanger.
Catalogue
Equipment reference
| Part Number | Model / Designation | Compatibility | Band / Interface | Condition | Lead Time | Quote |
|---|---|---|---|---|---|---|
| 10149-316 | nVent SCHROFF outdoor modular HEX cabinet, double door, 29U | 19-inch telecom / railway electronics; 48 V DC heat exchanger in door | 1510 × 1300 × 600 mm; 29U; door-mounted air-to-air heat exchanger max 70 W/K, 48 V DC, with heater and alarm outputs; double-walled aluminium, RAL 7035; IP55; 100 mm base; ETS 300 119 / IEC 61969 | On enquiry | On enquiry | |
| 11249-005 | nVent SCHROFF outdoor Unibody cabinet, single door, 20U | Low-dissipation 19-inch telecom / railway electronics | 1100 × 700 × 500 mm; 20U; natural convection max 6 W/K; double-walled aluminium; IP55 | On enquiry | On enquiry | |
| 11249-012 | nVent SCHROFF outdoor Unibody VENT cabinet, 25U | 19-inch telecom / railway electronics | 1330 × 700 × 500 mm; 25U; fan ventilation max 35 W/K; aluminium; IP55 | On enquiry | On enquiry | |
| 11249-016 | nVent SCHROFF outdoor Unibody HEX cabinet, 25U | 19-inch telecom / railway electronics | 1330 × 700 × 500 mm; 25U; door-mounted heat exchanger max 70 W/K; double-walled aluminium; IP55 | On enquiry | On enquiry | |
| 12349-010 | nVent SCHROFF outdoor Comline ECL cabinet, without plinth, 18U | 19-inch telecom / railway electronics | 900 × 600 × 500 mm; 18U; natural convection; powder-coated aluminium; IP55; 75 kg net | On enquiry | On enquiry | |
| 2000005172 | EnerSys SiteFlex LCC 16-12F outdoor battery cabinet, 4-tier, 12 V blocks, direct air cooling | Battery backup for outdoor telecom sites; SBS 170F / 190F / 210F 12 V (other types on consultation with manufacturer) | 1927 × 730 × 656 mm; 150 kg; DAC 1000 W at ΔT <5 K; IP45; −33 to +55 °C | On enquiry | On enquiry | |
| 2000005173 | EnerSys SiteFlex LCC 16-12A outdoor battery cabinet, 4-tier, 12 V blocks, air-conditioned | Battery backup for outdoor telecom sites; SBS 170F / 190F / 210F 12 V (other types on consultation with manufacturer) | 1992 × 730 × 696 mm; 170 kg; air conditioner 550 W at 35/35 °C (230 W consumption); IP45; −33 to +55 °C | On enquiry | On enquiry | |
| 2000005283 | EnerSys SiteFlex LCC 24-2F outdoor battery cabinet, 6-tier, 2 V cells, direct air cooling | Battery backup for outdoor telecom sites; SBS 580 2 V cells (other types on consultation with manufacturer) | 1927 × 730 × 656 mm; 170 kg; DAC 1000 W at ΔT <5 K; IP45; −33 to +55 °C | On enquiry | On enquiry | |
| 2000005284 | EnerSys SiteFlex LCC 24-2A outdoor battery cabinet, 6-tier, 2 V cells, air-conditioned | Battery backup for outdoor telecom sites; SBS 580 2 V cells (other types on consultation with manufacturer) | 1992 × 730 × 696 mm; 190 kg; air conditioner 550 W at 35/35 °C (230 W consumption); IP45; −33 to +55 °C | On enquiry | On enquiry | |
| 2000005674 | EnerSys SiteFlex MPC outdoor power and battery enclosure | Factory-fitted 4U 48 V DC 12 kW power system with Cordex 3 kW rectifiers (ordered separately) and 3U AC distribution; one 48 V string of PowerSafe 12V62F or 12V38F; stacks or bays with 2000005675 | 800 × 700 × 690 mm; 75 kg; 19-inch, 10U; direct air cooling, 1500 W at ΔT 10 K; IP54 (EN 60529); −33 to +55 °C; 0–100 % RH; options: plinth 2000003611, heater 2000003612, side-by-side kit 2000003601, wall / pole kit 2000003614 | On enquiry | On enquiry | |
| 2000005675 | EnerSys SiteFlex MPC outdoor equipment enclosure | 19-inch customer equipment (baseband, transmission); stacks on or bays beside 2000005674; no battery | 45 kg; 19-inch, 16U; direct air cooling, 3000 W at ΔT 10 K; IP54 (EN 60529); −33 to +55 °C; 0–100 % RH; dimensions confirmed per quotation | On enquiry | On enquiry | |
| 2000005676 | EnerSys SiteFlex Secure (SPBS) outdoor power and battery solution, theft-resistant | 5U 48 V DC 24 kW power system (Cordex 3 kW rectifiers ordered separately), 3U AC distribution, 4U free 19-inch customer space; 4 strings of 12 V SBS 170 / 190 Ah, or 1 string OPzV 600 2 V on request | Power bay direct air cooling 1400 W at ΔT 10 K, IP54; battery bay air conditioner 800 W at 35/35 °C (R134a), IP44; −10 to +50 °C; overall dimensions and weight confirmed per quotation | On enquiry | On enquiry | |
| 2000005682 | EnerSys SiteFlex LCC 8-12A outdoor battery cabinet, 2-tier, 12 V blocks, air-conditioned | Battery backup for outdoor telecom sites; SBS 170F / 190F / 210F 12 V (other types on consultation with manufacturer) | 1282 × 780 × 696 mm; 110 kg; air conditioner 550 W at 35/35 °C (230 W consumption); IP45; −33 to +55 °C | On enquiry | On enquiry | |
| 2000005698 | EnerSys SiteFlex LCC 8-12F outdoor battery cabinet, 2-tier, 12 V blocks, direct air cooling | Battery backup for outdoor telecom sites; SBS 170F / 190F / 210F 12 V (other types on consultation with manufacturer) | 1282 × 780 × 696 mm; 95 kg; DAC 1000 W at ΔT <5 K; IP45; −33 to +55 °C | On enquiry | On enquiry | |
| A-100324 | ANDREW Mini G outdoor cabinet, micro cell site enclosure | Small-cell radio and transmission equipment; no internal battery | 1041 × 1041 × 356 mm; 130 kg net; 4U; 1 × 175 mm fan; IP55; 230 V AC single-phase, 16–20 A input; 2 × 800 W rectifiers | On enquiry | On enquiry | |
| A-100471 | ANDREW Lancaster outdoor macro cell site enclosure, combiner space (NSN configuration) | Macro site radio / combiner equipment; 3 rectifiers; 4 batteries | 1651 × 1905 × 787 mm; 450 kg net; 18U (19-inch); 2 × 225 mm fans; IP55; 230 V AC single-phase, 50 A input; 3 × 3000 W rectifiers; battery string max 44 Ah at 48 V DC | On enquiry | On enquiry | |
| A-100534 | ANDREW outdoor transmission cabinet, micro cell site enclosure | 19-inch transmission / backhaul equipment; plinth or rooftop mount; 4 batteries | 1422 × 610 × 610 mm; 110 kg net; 18U (19-inch); 1 × 175 mm fan; IP55 (IEC 60529); 230 V AC single-phase; 1U PSU 1.6 kW max, 2 × 800 W rectifiers; 8-way AC and 8-way DC distribution; battery string 33 Ah at 48 V DC | On enquiry | On enquiry | |
| A-100573 | ANDREW Pogona outdoor cabinet, micro cell site enclosure | 19-inch radio and transmission equipment; plinth or rooftop mount; no internal battery | 1041 × 1219 × 406 mm; 140 kg net; 12U; 2 × 175 mm fans; IP55 (IEC 60529); 230 V AC single-phase, 32 A input; 2 × 2000 W rectifiers | On enquiry | On enquiry | |
| A-100586 | ANDREW Komodo outdoor cabinet, compact / micro cell site enclosure | 19-inch radio and transmission equipment; no internal battery | 1549 × 1219 × 406 mm; 185 kg net; 24U; 2 × 175 mm fans; IP55; 230 V AC single-phase, 32 A input; 3 × 2000 W rectifiers | On enquiry | On enquiry | |
| CS 9774.510 | Rittal CS Toptec outdoor enclosure, 600 × 1800 × 600 mm | TS 8 frame for 19-inch telecom and power equipment; climate control fitted separately | W × H × D 600 × 1800 × 600 mm; 86 kg net; stainless-steel 1.4301 frame, double-walled AlMg3 panels, RAL 7035; IP55 (IEC 60529); NEMA 3R / 12; IK10 | On enquiry | On enquiry | |
| CS 9781.866 | Rittal CS Toptec bayable outdoor enclosure, 800 × 1600 × 600 mm | TS 8 frame for 19-inch telecom and power equipment; climate control fitted separately; bayable side panels needed for stand-alone use | W × H × D 800 × 1600 × 600 mm; 1745 mm overall incl. 100 mm plinth and 45 mm rain canopy; 71.5 kg net; stainless-steel 1.4301 frame, double-walled AlMg3 panels, RAL 7035; IP55; NEMA 3R / 12; IK10 | On enquiry | On enquiry | |
| CS 9781.868 | Rittal CS Toptec bayable outdoor enclosure, 800 × 1600 × 800 mm | TS 8 frame for 19-inch telecom, power and battery equipment; climate control (Blue e+ Outdoor or heat exchanger) fitted separately; bayable side panels needed for stand-alone use | W × H × D 800 × 1600 × 800 mm; 1745 mm overall incl. 100 mm plinth and 45 mm rain canopy; 76 kg net; stainless-steel 1.4301 frame, double-walled AlMg3 panels, RAL 7035; IP55; NEMA 3R / 12; IK10; 4-point lock; UL / C-UL listed | On enquiry | On enquiry | |
| eSite x10 | Flexenclosure eSite x10 sealed hybrid power system for outdoor telecom sites | Grid / diesel genset / battery hybrid site power; up to three tenants with separate load metering; eSite Tools monitoring | IP65 sealed, tamper-proof; passive convection cooling, no filters or moving parts; soft power switching between grid and gensets; hand-portable; CE and ETSI certified; design life >10 years | On enquiry | On enquiry |
Cannot find a part number? Send us the number and we will identify and price it.
Ordering notes
Give the equipment to be housed in U and its heat load in watts, the DC load in amperes, the battery autonomy, the AC supply and the ambient range; the climate option and the rectifier count follow from those. Published weights generally exclude batteries, and for Rittal enclosures the climate unit, so specify both for freight. Certificates and country approvals for the destination are requested per configuration. No list price is published; quotations are per cabinet with the configuration itemised — housing, plinth, climate unit, power system, monitoring and batteries — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.
Lifecycle and availability
Availability of each model is confirmed per quotation. Some of the enclosures listed, including earlier ANDREW site enclosures and the Flexenclosure eSite system, are offered from the used and surplus market; where a model has been superseded, the current equivalent is proposed alongside it on the quotation.
Equipment condition
New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.
New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.
Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.
Condition is confirmed in writing on every quotation before you commit to an order.
Warranty
Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.
Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.
Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.
Refurbished stock — how it is graded and what ships
New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.
- Cosmetic grade.Is the housing new?
- Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
- Test coverage.Is it fully working?
- Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
- What ships with the cabinet.With plinth, keys and internal fittings?
- The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
- Warranty on used stock.What warranty?
- Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
- Firmware state.Is the firmware in English, and is it locked?
- The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
- Licence state (OLT chassis and control boards).What about licences on a used OLT?
- Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.
Questions
Frequently asked questions
Do these cabinets come with the power system and climate unit?
It depends on the range. The EnerSys SiteFlex MPC power and battery enclosure is supplied with a factory-fitted 48 V DC power system and AC distribution, with the rectifier modules specified per order. ANDREW site enclosures are configured with rectifiers and battery space as defined by the part number. Rittal CS Toptec enclosures are supplied as the enclosure system, and the climate control unit is ordered separately. nVent SCHROFF outdoor cabinets are ordered by cooling version — natural convection, fan ventilation or door-mounted heat exchanger. In every case the quotation lists the housing, climate unit, power system and batteries as separate lines.
What is included with a cabinet — rectifiers, batteries, climate unit, plinth?
Manufacturer weights are almost always quoted without rectifier modules and batteries, and dealer listings often say only "equipped cabinet". Every quotation from CRS PLUS itemises what ships: the housing, base frame or plinth, climate unit (heat exchanger, air conditioner or ventilation), rectifier frame and the number of modules fitted, monitoring unit, busbars, breakers and surge protection, battery trays and whether batteries are supplied. Ask for the packing list before comparing prices between sources.
Which climate variant suits a hot-climate site?
Heat-exchanger cabinets are sealed and suit most sites; direct-ventilation battery bays carry a lower ingress rating and suit cleaner, cooler locations; air-conditioned variants are specified where ambient temperature or solar load would otherwise shorten battery life. State the site's ambient range and whether the cabinet is in the sun and the quotation will say which variant is proposed and why.
Can these enclosures house Huawei, Ericsson or Nokia equipment?
Enclosures with open 19-inch space accept any 19-inch, −48 V DC baseband, transport or radio equipment. What must be checked is the heat load against the climate unit, the DC breaker count and rating, cable entry and the alarm interface, since these enclosures expose dry contacts or SNMP rather than the radio vendor's own site management protocol. State the equipment to be housed and the quotation will confirm the fit.
How are cabinets shipped and how long does it take?
Cabinets are crated or palletised and normally move by sea because of volume; air freight is quoted where the schedule demands it. Dispatch time and transit time are stated separately on the quotation. Lithium batteries are dangerous goods in transit, so cabinets are usually shipped without batteries unless DG-compliant freight is arranged.
What warranty applies, and what does it cover on used cabinets?
Warranty terms are stated per line item on the quotation, for new and refurbished cabinets alike. On refurbished units the warranty covers functional failure of the climate unit, power frame and monitoring under normal use; the period, exclusions and return procedure are set out in writing before you commit to an order.
Related pages
Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.
This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 7 November 2026.
Need a part number from Outdoor Cabinets & Enclosures?
A structured offer follows within 72 hours.