Vertiv, Delta, Eltek · Outdoor Cabinets & Enclosures
Vertiv, Delta and Eltek outdoor cabinets — ECM3, OutD and Outdoor Type 3 / Type 4
Where a buyer does not need a Huawei or Ericsson housing, the vendor-neutral cabinets from Vertiv, Delta and Eltek carry any 19-inch, −48 V DC baseband, transport or radio equipment with an embedded power system and battery strings. Vertiv's ECM3 is the closest like-for-like to an Enclosure 6150 class cabinet, Delta's OutD range runs from pole-mount enclosures to 42 kW site cabinets, and Eltek's Outdoor Type 3 and Type 4 bodies are configured with Flatpack2 rectifier systems per order. A Vertiv NetSure 731 power cabinet set has also been quoted recently from the used market. The table lists the models with dimensions, user space, climate options and power ratings from the vendors' datasheets.
How to read these part numbers
Vertiv ECM3 is sold as ECM3-14 (750 × 750 × 1685 mm, 31U) and ECM3-18 (900 × 900 × 2085 mm, 40U), each in single, double or triple bays bolted together; the embedded power is NetSure 731 — A41-S7 for 200 A or A61-S2/S3 for 300 A — with the M530S controller. NetSure X701 two-bay and three-bay enclosures are North American NEMA builds. Delta designations read ESOA or ESOF, a three-digit number and a three-letter cabinet variant — ESOA300-HAV, ESOF006-EBB — where ESOA series state capacity in kW and ESOF series mostly in amperes, and the last three letters separate cooling and compartment variants (fan, heat exchanger, DC air conditioner, thermoelectric). Delta publishes dimensions as W × H × D. Eltek Outdoor Type 3 and Type 4 are cabinet bodies: Type 3 comes in five heights (1.2–2.2 m, 21–44U, 700 mm wide), Type 4 in 1.5 m (27U) and 2.0 m (39U), and the power system fitted into them is given a configured part number of the form CTxxxxxx.nnnn. Eltek has been part of Delta Electronics since 2015.
Equipment reference
34 of 34 items
| Part Number | Model / Designation | Compatibility | Band / Interface | Condition | Lead Time | |
|---|---|---|---|---|---|---|
| BXSB04Also: 4U / 24U / 30U / 42U variants | Vertiv Outdoor Cabinet Single, single-bay NEMA cabinet (North America) | 19-inch or 23-inch EIA rails; door-mounted AC or heat exchanger; 4 / 12 / 16 in battery plinth | Depth 32 or 36 in; 4U, 24U, 30U or 42U; NEMA 3R or 4; heavy-gauge aluminium; weight and temperature confirmed per quotation | On enquiry | On enquiry | |
| CTEA0828R.401.DS3 | Eltek solar-powered outdoor cabinet, Flatpack2 + Rectiverters | Up to 8 × Flatpack2 1500 W HE + 8 (1-ph) or 12 (3-ph) Rectiverters; PV input up to 12 kW; AC out 9.6 / 14.4 kW; 48 V DC battery, 2 strings | 1500 × 700 × 823 mm; 150–160 kg excl. rectifiers and batteries; fan / filter cooling; IP55; −40 to +50 °C | On enquiry | On enquiry | |
| CTO31240.nnnn | Eltek Flatpack2 36 kW Outdoor Power System in Type 4 body | Flatpack2 48/3000 SHE rectifiers, 36 kW / 700 A at 57.6 V DC; 3-phase 400 V input; Smartpack R controller; 8 battery breakers, 16 load MCBs, LVBD 800 A | 2068 × 705 × 831 mm; ≈168 kg excl. modules; 39U; dual-fan cooling (2500 W fan filter optional); IP55; −40 to +45 °C | On enquiry | On enquiry | |
| ECM3-14Also: single / double / triple bay | Vertiv ECM3-14 outdoor telecom enclosure with embedded NetSure 731 power | NetSure 731 A41-S7 (200 A, 7U) or A61-S2/S3 (300 A, 11U); M530S controller; 50 A rectifiers; input 80–300 V AC | 1685 × 750 × 750 mm single (≤250 kg); 1500 / 2250 mm wide double / triple; 31U; heat exchanger 180 W/K or air conditioner (300 W DC / 1500 W AC); 4-layer battery bay 560 × 600 × 330 mm; IP55 / IP44; −10 to +65 °C (−40 °C with heater) | On enquiry | On enquiry | |
| ECM3-18Also: single / double / triple bay | Vertiv ECM3-18 outdoor telecom enclosure with embedded NetSure 731 power | NetSure 731 A41-S7 (200 A) or A61-S2/S3 (300 A); M530S; up to 300 A load | 2085 × 900 × 900 mm single (≤280 kg); 1800 / 2700 mm wide double / triple; 40U (23U + 2-layer battery integrated variant); heat exchanger 180 W/K or air conditioner; IP55 / IP44; −10 to +65 °C (−40 °C with heater); efficiency >96 % | On enquiry | On enquiry | |
| Eltek MicrocabinetAlso: datasheet ds-2140459 | Eltek Microcabinet outside-plant cabinet with Micropack | Micropack 48 / 24 / 12 V DC, max 1000 W; up to two battery strings 12–40 Ah; 13 RU | 26 × 23 × 11 in (≈660 × 584 × 280 mm); side-to-side fan filter with IP55 filter; optional battery heater pads; weight confirmed per quotation | On enquiry | On enquiry | |
| ESOA015-HAC | Delta OutD ESOA015-HAC compact outdoor power system | 850 W N+1; 2U shelf | 1350 × 765 × 814 mm; ≈100 kg excl. battery; fan cooling; 0 to +60 °C; IP confirmed per quotation | On enquiry | On enquiry | |
| ESOA020-HCU | Delta OutD ESOA020-HCU small TEC-cooled outdoor power enclosure | Up to 1000 W at 200 / 230 V AC | 335 × 488 × 484 mm as printed; ≈57 kg; thermoelectric cooling; IP55; −40 to +46 °C | On enquiry | On enquiry | |
| ESOA050-HEA | Delta OutD ESOA050-HEA small outdoor power system with Li-ion battery | 2900 W at 200 V AC / 1500 W at 100 V AC; 48 V / 50 Ah Li-ion in 3U | 630 × 610 × 530 mm as printed; 84 kg (fan) to 97 kg (air conditioner); fan, HEX or AC options; IP55; −20 to +45 °C | On enquiry | On enquiry | |
| ESOA060-HBA | Delta OutD ESOA060-HBA wall / pole outdoor power enclosure | 3480 W, 2 rectifier slots | 286 × 550 × 600 mm as printed; ≈20 kg excl. rectifier and battery; fan; IP55; −20 to +55 °C | On enquiry | On enquiry | |
| ESOA300-CAA | Delta OutD ESOA300-CAA outdoor cabinet, fan + TEC | Max 17.4 kW; intelligent controller and adaptable PDUs | 2000 × 700 × 700 mm; ≈150 kg empty; fan + thermoelectric cooling; IP55; 0 to +45 °C | On enquiry | On enquiry | |
| ESOA300-HAC | Delta OutD ESOA300-HAC outdoor power system cabinet | Max 8.7 kW; 6U power shelf; 2 banks of 200 Ah | 2150 × 750 × 800 mm; ≈220 kg excl. rectifiers; fan cooling; −10 to +50 °C; IP confirmed per quotation | On enquiry | On enquiry | |
| ESOA300-HAF | Delta OutD ESOA300-HAF outdoor power system cabinet | Max 17.4 kW; battery space for 8 × 12 V blocks | 2060 × 800 × 750 mm; ≈170 kg; 16U; fan 250 W/K; IP55; −10 to +45 °C | On enquiry | On enquiry | |
| ESOA300-HAF Hybrid | Delta OutD ESOA300-HAF Hybrid, rectifier + PV charger cabinet | 17.4 kW rectifier + 13.2 kW PV charger | 2060 × 800 × 750 mm; ≈170 kg; fan 250 W/K; IP55; 0 to +50 °C; U space confirmed per quotation | On enquiry | On enquiry | |
| ESOA300-HAH | Delta OutD ESOA300-HAH outdoor power system cabinet, fan-cooled | −54 V DC default; max 20 kW; 220 V single or 380 V three-phase; 2 banks of 150 Ah | 2000 × 790 × 650 mm without external cooling units; ≈76 kg empty; 20U; fan cooling; −10 to +50 °C; RoHS; IP confirmed per quotation | On enquiry | On enquiry | |
| ESOA300-HAJ | Delta OutD ESOA300-HAJ compact outdoor cabinet | Max 12 kW; 5U power system; 96.4 % rectifier efficiency | 1500 × 750 × 750 mm; ≈110 kg excl. battery; fan cooling; IP55; −40 to +50 °C | On enquiry | On enquiry | |
| ESOA300-HAV | Delta OutD ESOA300-HAV outdoor power system cabinet, air-conditioned or fan | −54 V DC (−43 to −58 V); max 17.4 kW; rectifier model and battery confirmed per quotation | 2060 × 800 × 800 mm (W × H × D 800 × 2060 × 800); ≈170 kg; air conditioner 1333 / 1200 W or fan 250 W/K; IP55; −10 to +55 °C | On enquiry | On enquiry | |
| ESOA400-HCU | Delta OutD ESOA400-HCU outdoor power system cabinet (North America size) | Max 21.6 kW; high-density rectifiers | 1829 × 762 × 1041 mm (72 × 30 × 41 in); ≈276 kg; fan cooling with speed control; IP55; −40 to +50 °C | On enquiry | On enquiry | |
| ESOA400-QBA | Delta OutD ESOA400-QBA outdoor cabinet with separate battery compartment | Max 21 kW; rectifiers separate; TEC-cooled battery section | 2060 × 800 × 800 mm; ≈180 kg without rectifiers and battery; HEX 80 W/K upper + TEC battery compartment; IP55; 0 to +45 °C | On enquiry | On enquiry | |
| ESOF001-EAB | Delta OutD ESOF001-EAB outdoor cabinet, heat-exchanger cooled | Any Delta DC or AC power system with battery backup | 2000 × 790 × 650 mm without external units; ≈76 kg empty; modular HEX with multi-stage fan control; −10 to +50 °C; IP confirmed per quotation | On enquiry | On enquiry | |
| ESOF001-EAC | Delta OutD ESOF001-EAC compact battery / equipment cabinet | 2 banks of 200 Ah; power system confirmed per quotation | 1350 × 765 × 814 mm; ≈100 kg excl. battery; fan cooling; 0 to +60 °C; IP confirmed per quotation | On enquiry | On enquiry | |
| ESOF006-EBB | Delta OutD ESOF006-EBB outdoor cabinet with DC air conditioner | −48 V DC battery-type input; −54 V DC output | 2100 × 800 × 800 mm; ≈190 kg; 300 W DC air conditioner; IP55; 0 to +45 °C; RoHS | On enquiry | On enquiry | |
| ESOF009-EAA | Delta OutD ESOF009-EAA outdoor cabinet | 200 A max; rectifiers and battery confirmed per quotation | 2060 × 850 × 850 mm; ≈170 kg; fan 250 W/K; IP55; −10 to +55 °C | On enquiry | On enquiry | |
| ESOF010-ECV | Delta OutD ESOF010-ECV single-bay 50 RU cabinet | 116 A max | 2512 × 864 × 1260 mm; ≈462 kg empty; thermosiphon heat exchanger; 50 RU; IP55; −40 to +50 °C | On enquiry | On enquiry | |
| ESOF016-ECA | Delta OutD ESOF016-ECA outdoor cabinet | 190 A max | 1881 × 828 × 1156 mm; ≈262 kg empty; air conditioner + fan; IP55; 0 to +46 °C | On enquiry | On enquiry | |
| ESOF024-ECB | Delta OutD ESOF024-ECB outdoor cabinet | 600 A max | 1830 × 810 × 850 mm; ≈300 kg empty; TEC cooling; IP55; 0 to +46 °C | On enquiry | On enquiry | |
| ESOF028-ECB | Delta OutD ESOF028-ECB outdoor cabinet | 54 V DC, 57 A or 46 A max | 2133 × 857 × 1156 mm; ≈395 kg empty; air conditioner + TEC (fan option); IP55; 0 to +46 °C | On enquiry | On enquiry | |
| ESOF030-HCU | Delta OutD ESOF030-HCU large outdoor system | 224 A max | 2601 × 1932 × 1338 mm as printed plus 4 in plinth; ≈1107 kg excl. batteries; thermosiphon HEX; IP55; −40 to +46 °C | On enquiry | On enquiry | |
| F2020029 | Vertiv NetSure X701 multi-bay outdoor enclosure, two-bay (North America) | Factory-integrated NetSure 512 (−48 / −58 V DC); eSure 40 A / 2000 W rectifiers; 3 VRLA strings ≤210 Ah | 86 × 68 × 54 in (≈2184 × 1727 × 1372 mm); ≈590 kg; 43 RU; closed-loop heat exchangers 6000 W + 2800 W; aluminium; −40 to +46 °C; UL 2416, UL 50E | On enquiry | On enquiry | |
| F2020030 | Vertiv NetSure X701 multi-bay outdoor enclosure, three-bay (North America) | As two-bay | 74 × 102 × 54 in as printed; ≈748 kg; 76 RU; two 6000 W equipment chambers + 2800 W power chamber; −40 to +46 °C; UL 2416, UL 50E | On enquiry | On enquiry | |
| NetSure 731 A91-S2 | Vertiv NetSure 731 power cabinet set | Vertiv −48 V DC site power; quoted used-original as a complete set | Configuration and dimensions confirmed per quotation | On enquiry | On enquiry | |
| Outdoor Type 3Also: 1.2 / 1.5 / 1.8 / 2.0 / 2.2 m; single, dual, two-chamber | Eltek Outdoor Type 3 cabinet body, galvanised steel (aluminium optional) | Eltek Flatpack2 / Smartpack power systems and 19-inch equipment; up to 4 battery trays (≤260 kg per tray) | 1200–2200 × 700 × 770 mm; 21 / 28 / 34 / 39 / 44U; 69–105 kg excl. cooling; fan filter 2000 W, air conditioner 520–2000 W, heat exchanger 100 W/K (+202 mm depth) or hybrids up to 3000 W + 120 W/K; IP55, NEMA 3R | On enquiry | On enquiry | |
| Outdoor Type 4 1.5 m | Eltek Outdoor Type 4 cabinet, 1.5 m | Eltek power systems configured in (CTxxxxxx.nnnn); battery trays ≤280 kg | 1456 × 705 × 772 mm without thermal unit; 61 kg (+27 kg thermal unit); 27U; fan filter 1700 W single / 2500 W dual at ΔT 10 °C; up to two 500 W heaters; IP55 | On enquiry | On enquiry | |
| Outdoor Type 4 2.0 m | Eltek Outdoor Type 4 cabinet, 2.0 m | As Type 4 1.5 m | 2068 × 705 × 772 mm without thermal unit; 67 kg (+37 kg thermal unit); 39U; fan filter 1700 / 2500 W; two 500 W heaters; IP55 | On enquiry | On enquiry |
BXSB04
Also: 4U / 24U / 30U / 42U variants
- Model
- Vertiv Outdoor Cabinet Single, single-bay NEMA cabinet (North America)
- Compatibility
- 19-inch or 23-inch EIA rails; door-mounted AC or heat exchanger; 4 / 12 / 16 in battery plinth
- Band / Interface
- Depth 32 or 36 in; 4U, 24U, 30U or 42U; NEMA 3R or 4; heavy-gauge aluminium; weight and temperature confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
CTEA0828R.401.DS3
- Model
- Eltek solar-powered outdoor cabinet, Flatpack2 + Rectiverters
- Compatibility
- Up to 8 × Flatpack2 1500 W HE + 8 (1-ph) or 12 (3-ph) Rectiverters; PV input up to 12 kW; AC out 9.6 / 14.4 kW; 48 V DC battery, 2 strings
- Band / Interface
- 1500 × 700 × 823 mm; 150–160 kg excl. rectifiers and batteries; fan / filter cooling; IP55; −40 to +50 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
CTO31240.nnnn
- Model
- Eltek Flatpack2 36 kW Outdoor Power System in Type 4 body
- Compatibility
- Flatpack2 48/3000 SHE rectifiers, 36 kW / 700 A at 57.6 V DC; 3-phase 400 V input; Smartpack R controller; 8 battery breakers, 16 load MCBs, LVBD 800 A
- Band / Interface
- 2068 × 705 × 831 mm; ≈168 kg excl. modules; 39U; dual-fan cooling (2500 W fan filter optional); IP55; −40 to +45 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ECM3-14
Also: single / double / triple bay
- Model
- Vertiv ECM3-14 outdoor telecom enclosure with embedded NetSure 731 power
- Compatibility
- NetSure 731 A41-S7 (200 A, 7U) or A61-S2/S3 (300 A, 11U); M530S controller; 50 A rectifiers; input 80–300 V AC
- Band / Interface
- 1685 × 750 × 750 mm single (≤250 kg); 1500 / 2250 mm wide double / triple; 31U; heat exchanger 180 W/K or air conditioner (300 W DC / 1500 W AC); 4-layer battery bay 560 × 600 × 330 mm; IP55 / IP44; −10 to +65 °C (−40 °C with heater)
- Condition
- On enquiry
- Lead Time
- On enquiry
ECM3-18
Also: single / double / triple bay
- Model
- Vertiv ECM3-18 outdoor telecom enclosure with embedded NetSure 731 power
- Compatibility
- NetSure 731 A41-S7 (200 A) or A61-S2/S3 (300 A); M530S; up to 300 A load
- Band / Interface
- 2085 × 900 × 900 mm single (≤280 kg); 1800 / 2700 mm wide double / triple; 40U (23U + 2-layer battery integrated variant); heat exchanger 180 W/K or air conditioner; IP55 / IP44; −10 to +65 °C (−40 °C with heater); efficiency >96 %
- Condition
- On enquiry
- Lead Time
- On enquiry
Eltek Microcabinet
Also: datasheet ds-2140459
- Model
- Eltek Microcabinet outside-plant cabinet with Micropack
- Compatibility
- Micropack 48 / 24 / 12 V DC, max 1000 W; up to two battery strings 12–40 Ah; 13 RU
- Band / Interface
- 26 × 23 × 11 in (≈660 × 584 × 280 mm); side-to-side fan filter with IP55 filter; optional battery heater pads; weight confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA015-HAC
- Model
- Delta OutD ESOA015-HAC compact outdoor power system
- Compatibility
- 850 W N+1; 2U shelf
- Band / Interface
- 1350 × 765 × 814 mm; ≈100 kg excl. battery; fan cooling; 0 to +60 °C; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA020-HCU
- Model
- Delta OutD ESOA020-HCU small TEC-cooled outdoor power enclosure
- Compatibility
- Up to 1000 W at 200 / 230 V AC
- Band / Interface
- 335 × 488 × 484 mm as printed; ≈57 kg; thermoelectric cooling; IP55; −40 to +46 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA050-HEA
- Model
- Delta OutD ESOA050-HEA small outdoor power system with Li-ion battery
- Compatibility
- 2900 W at 200 V AC / 1500 W at 100 V AC; 48 V / 50 Ah Li-ion in 3U
- Band / Interface
- 630 × 610 × 530 mm as printed; 84 kg (fan) to 97 kg (air conditioner); fan, HEX or AC options; IP55; −20 to +45 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA060-HBA
- Model
- Delta OutD ESOA060-HBA wall / pole outdoor power enclosure
- Compatibility
- 3480 W, 2 rectifier slots
- Band / Interface
- 286 × 550 × 600 mm as printed; ≈20 kg excl. rectifier and battery; fan; IP55; −20 to +55 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-CAA
- Model
- Delta OutD ESOA300-CAA outdoor cabinet, fan + TEC
- Compatibility
- Max 17.4 kW; intelligent controller and adaptable PDUs
- Band / Interface
- 2000 × 700 × 700 mm; ≈150 kg empty; fan + thermoelectric cooling; IP55; 0 to +45 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-HAC
- Model
- Delta OutD ESOA300-HAC outdoor power system cabinet
- Compatibility
- Max 8.7 kW; 6U power shelf; 2 banks of 200 Ah
- Band / Interface
- 2150 × 750 × 800 mm; ≈220 kg excl. rectifiers; fan cooling; −10 to +50 °C; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-HAF
- Model
- Delta OutD ESOA300-HAF outdoor power system cabinet
- Compatibility
- Max 17.4 kW; battery space for 8 × 12 V blocks
- Band / Interface
- 2060 × 800 × 750 mm; ≈170 kg; 16U; fan 250 W/K; IP55; −10 to +45 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-HAF Hybrid
- Model
- Delta OutD ESOA300-HAF Hybrid, rectifier + PV charger cabinet
- Compatibility
- 17.4 kW rectifier + 13.2 kW PV charger
- Band / Interface
- 2060 × 800 × 750 mm; ≈170 kg; fan 250 W/K; IP55; 0 to +50 °C; U space confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-HAH
- Model
- Delta OutD ESOA300-HAH outdoor power system cabinet, fan-cooled
- Compatibility
- −54 V DC default; max 20 kW; 220 V single or 380 V three-phase; 2 banks of 150 Ah
- Band / Interface
- 2000 × 790 × 650 mm without external cooling units; ≈76 kg empty; 20U; fan cooling; −10 to +50 °C; RoHS; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-HAJ
- Model
- Delta OutD ESOA300-HAJ compact outdoor cabinet
- Compatibility
- Max 12 kW; 5U power system; 96.4 % rectifier efficiency
- Band / Interface
- 1500 × 750 × 750 mm; ≈110 kg excl. battery; fan cooling; IP55; −40 to +50 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA300-HAV
- Model
- Delta OutD ESOA300-HAV outdoor power system cabinet, air-conditioned or fan
- Compatibility
- −54 V DC (−43 to −58 V); max 17.4 kW; rectifier model and battery confirmed per quotation
- Band / Interface
- 2060 × 800 × 800 mm (W × H × D 800 × 2060 × 800); ≈170 kg; air conditioner 1333 / 1200 W or fan 250 W/K; IP55; −10 to +55 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA400-HCU
- Model
- Delta OutD ESOA400-HCU outdoor power system cabinet (North America size)
- Compatibility
- Max 21.6 kW; high-density rectifiers
- Band / Interface
- 1829 × 762 × 1041 mm (72 × 30 × 41 in); ≈276 kg; fan cooling with speed control; IP55; −40 to +50 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOA400-QBA
- Model
- Delta OutD ESOA400-QBA outdoor cabinet with separate battery compartment
- Compatibility
- Max 21 kW; rectifiers separate; TEC-cooled battery section
- Band / Interface
- 2060 × 800 × 800 mm; ≈180 kg without rectifiers and battery; HEX 80 W/K upper + TEC battery compartment; IP55; 0 to +45 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF001-EAB
- Model
- Delta OutD ESOF001-EAB outdoor cabinet, heat-exchanger cooled
- Compatibility
- Any Delta DC or AC power system with battery backup
- Band / Interface
- 2000 × 790 × 650 mm without external units; ≈76 kg empty; modular HEX with multi-stage fan control; −10 to +50 °C; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF001-EAC
- Model
- Delta OutD ESOF001-EAC compact battery / equipment cabinet
- Compatibility
- 2 banks of 200 Ah; power system confirmed per quotation
- Band / Interface
- 1350 × 765 × 814 mm; ≈100 kg excl. battery; fan cooling; 0 to +60 °C; IP confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF006-EBB
- Model
- Delta OutD ESOF006-EBB outdoor cabinet with DC air conditioner
- Compatibility
- −48 V DC battery-type input; −54 V DC output
- Band / Interface
- 2100 × 800 × 800 mm; ≈190 kg; 300 W DC air conditioner; IP55; 0 to +45 °C; RoHS
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF009-EAA
- Model
- Delta OutD ESOF009-EAA outdoor cabinet
- Compatibility
- 200 A max; rectifiers and battery confirmed per quotation
- Band / Interface
- 2060 × 850 × 850 mm; ≈170 kg; fan 250 W/K; IP55; −10 to +55 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF010-ECV
- Model
- Delta OutD ESOF010-ECV single-bay 50 RU cabinet
- Compatibility
- 116 A max
- Band / Interface
- 2512 × 864 × 1260 mm; ≈462 kg empty; thermosiphon heat exchanger; 50 RU; IP55; −40 to +50 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF016-ECA
- Model
- Delta OutD ESOF016-ECA outdoor cabinet
- Compatibility
- 190 A max
- Band / Interface
- 1881 × 828 × 1156 mm; ≈262 kg empty; air conditioner + fan; IP55; 0 to +46 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF024-ECB
- Model
- Delta OutD ESOF024-ECB outdoor cabinet
- Compatibility
- 600 A max
- Band / Interface
- 1830 × 810 × 850 mm; ≈300 kg empty; TEC cooling; IP55; 0 to +46 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF028-ECB
- Model
- Delta OutD ESOF028-ECB outdoor cabinet
- Compatibility
- 54 V DC, 57 A or 46 A max
- Band / Interface
- 2133 × 857 × 1156 mm; ≈395 kg empty; air conditioner + TEC (fan option); IP55; 0 to +46 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
ESOF030-HCU
- Model
- Delta OutD ESOF030-HCU large outdoor system
- Compatibility
- 224 A max
- Band / Interface
- 2601 × 1932 × 1338 mm as printed plus 4 in plinth; ≈1107 kg excl. batteries; thermosiphon HEX; IP55; −40 to +46 °C
- Condition
- On enquiry
- Lead Time
- On enquiry
F2020029
- Model
- Vertiv NetSure X701 multi-bay outdoor enclosure, two-bay (North America)
- Compatibility
- Factory-integrated NetSure 512 (−48 / −58 V DC); eSure 40 A / 2000 W rectifiers; 3 VRLA strings ≤210 Ah
- Band / Interface
- 86 × 68 × 54 in (≈2184 × 1727 × 1372 mm); ≈590 kg; 43 RU; closed-loop heat exchangers 6000 W + 2800 W; aluminium; −40 to +46 °C; UL 2416, UL 50E
- Condition
- On enquiry
- Lead Time
- On enquiry
F2020030
- Model
- Vertiv NetSure X701 multi-bay outdoor enclosure, three-bay (North America)
- Compatibility
- As two-bay
- Band / Interface
- 74 × 102 × 54 in as printed; ≈748 kg; 76 RU; two 6000 W equipment chambers + 2800 W power chamber; −40 to +46 °C; UL 2416, UL 50E
- Condition
- On enquiry
- Lead Time
- On enquiry
NetSure 731 A91-S2
- Model
- Vertiv NetSure 731 power cabinet set
- Compatibility
- Vertiv −48 V DC site power; quoted used-original as a complete set
- Band / Interface
- Configuration and dimensions confirmed per quotation
- Condition
- On enquiry
- Lead Time
- On enquiry
Outdoor Type 3
Also: 1.2 / 1.5 / 1.8 / 2.0 / 2.2 m; single, dual, two-chamber
- Model
- Eltek Outdoor Type 3 cabinet body, galvanised steel (aluminium optional)
- Compatibility
- Eltek Flatpack2 / Smartpack power systems and 19-inch equipment; up to 4 battery trays (≤260 kg per tray)
- Band / Interface
- 1200–2200 × 700 × 770 mm; 21 / 28 / 34 / 39 / 44U; 69–105 kg excl. cooling; fan filter 2000 W, air conditioner 520–2000 W, heat exchanger 100 W/K (+202 mm depth) or hybrids up to 3000 W + 120 W/K; IP55, NEMA 3R
- Condition
- On enquiry
- Lead Time
- On enquiry
Outdoor Type 4 1.5 m
- Model
- Eltek Outdoor Type 4 cabinet, 1.5 m
- Compatibility
- Eltek power systems configured in (CTxxxxxx.nnnn); battery trays ≤280 kg
- Band / Interface
- 1456 × 705 × 772 mm without thermal unit; 61 kg (+27 kg thermal unit); 27U; fan filter 1700 W single / 2500 W dual at ΔT 10 °C; up to two 500 W heaters; IP55
- Condition
- On enquiry
- Lead Time
- On enquiry
Outdoor Type 4 2.0 m
- Model
- Eltek Outdoor Type 4 cabinet, 2.0 m
- Compatibility
- As Type 4 1.5 m
- Band / Interface
- 2068 × 705 × 772 mm without thermal unit; 67 kg (+37 kg thermal unit); 39U; fan filter 1700 / 2500 W; two 500 W heaters; IP55
- Condition
- On enquiry
- Lead Time
- On enquiry
Cannot find a part number? Send us the number and we will identify and price it.
Ordering notes
Give the equipment to be housed in U and its heat load in watts, the DC load in amperes, the battery autonomy, the AC supply and the ambient range; the climate option is chosen from those — ECM3 heat exchanger 180 W/K or 1500 W air conditioner, Eltek Type 4 fan filter 1700 or 2500 W, Delta HAV air conditioner 1200–1333 W — and the rectifier count follows the load. Weights published by all three vendors exclude rectifier modules and batteries, so specify both for freight. Certificates and country approvals for the destination are requested per configuration because ratings differ by climate option. No list price is published; quotations are per cabinet with the configuration itemised — housing, climate unit, rectifier frame, modules, monitoring, batteries, plinth — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.
Lifecycle and availability
Vertiv ECM3, NetSure X701 and the Outdoor Cabinet Single are current catalogue items; the ECM3 product pages are partner-restricted and availability is confirmed per quotation. Delta OutD series pages are live for more than thirty ESOA / ESOF variants. Eltek Outdoor Type 3, Type 4 and the Flatpack2 36 kW outdoor system remain live products under the Eltek brand within Delta. None of the three vendors publishes end-of-life dates on these pages.
Choosing between a branded ODM cabinet and an OEM original
A vendor-neutral cabinet suits a site where the radio vendor may change, where the buyer wants a single cabinet standard across Huawei, Ericsson and Nokia sites, or where a used OEM enclosure is not acceptable to the operator. What it does not provide is the OEM's site monitoring integration: Vertiv M530S and Eltek Smartpack controllers expose dry contacts and SNMP rather than the Huawei or Ericsson management protocol, so alarm mapping is confirmed at design stage. Where the site is an existing OEM footprint, the plinth dimensions decide — ECM3-14 is 750 × 750 mm, ECM3-18 900 × 900 mm, Eltek Type 3 700 × 770 mm, Delta ESOA300 800 × 800 mm.
Equipment condition
New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.
New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.
Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.
Condition is confirmed in writing on every quotation before you commit to an order.
Warranty
Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.
Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.
Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.
Refurbished stock — how it is graded and what ships
New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.
- Is the housing new?
- Cosmetic grade. Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
- Is it fully working?
- Test coverage. Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
- With plinth, keys and internal fittings?
- What ships with the cabinet. The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
- What warranty?
- Warranty on used stock. Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
- Is the firmware in English, and is it locked?
- Firmware state. The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
- What about licences on a used OLT?
- Licence state (OLT chassis and control boards). Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.
Frequently asked questions
ECM3 ships with the embedded NetSure 731 power frame and controller, with rectifier modules specified per order. Delta OutD cabinets are sold with Delta rectifier shelves sized to the series capacity, rectifiers specified separately. Eltek Type 3 and Type 4 are bodies into which a Flatpack2 or Smartpack system is configured and given its own part number. In every case the quotation lists the frame, the modules fitted and the batteries as separate lines.
Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.